Selection of ultra-low temperature chiller supporting the glass reactor
In order to achieve an economical ultra-low temperature environment for glass reactors, many customers will not choose multi-stage compressor refrigeration equipment with more than two stages, but use liquid nitrogen. The cost of liquid nitrogen is low, and this refrigeration method is welcomed by some users, both in experiments and in production. However, due to the low boiling point of liquid nitrogen (minus 195.8°C), the latent heat is small and it is easy to evaporate. There are also big problems with using liquid nitrogen refrigerators safely.
In the storage, transportation and application of liquid nitrogen, it is necessary to have storage and application equipment with good thermal insulation performance. Most of the liquid nitrogen related equipment and pipeline fittings on the market adopt double-walled vacuum container structure. The key factor affecting the performance of this vacuum container and accessories is the vacuum degree of the interlayer. Moreover, the use of liquid nitrogen puts forward higher requirements on the reactor temperature control method, heat preservation measures, material properties, equipment sealing and pressure control, and environmental safety measures. Glass reactors cooled with liquid nitrogen must still retain the advantage of being transparent and visible during the reaction. Moreover, liquid nitrogen is a health hazard: skin contact with liquid nitrogen can cause frostbite. If the nitrogen produced by vaporization under normal pressure is excessive, the partial pressure of oxygen in the air will drop, causing hypoxia and suffocation. Guanya Refrigeration’s ultra-low temperature freezer adopts the single-machine cascade refrigeration process, and the low temperature can reach minus 150 degrees; it adopts the secondary supercooling technology, and the refrigeration is rapid.
Recommandations connexes
-
Quelles sont les précautions à prendre pour l'installation d'un refroidisseur au glycol ?
1046En été, l'utilisation des refroidisseurs de glycol est relativement fréquente. Par conséquent, lors de l'installation des refroidisseurs de glycol, il est nécessaire de les installer sur un sol lisse et propre. Pourquoi choisir un sol lisse lors de l'installation ? Les utilisateurs qui ont connu les refroidisseurs de glycol...
Voir les détails -
État de fonctionnement du dispositif de circulation de contrôle de la température pour l'épuration de la distillation à petite échelle
949Distillation reflux concentration and purification temperature-control circulating device is widely used in many fields. It is very important to select appropriate equipment, which can greatly improve product quality and reduce production costs t...
Voir les détails -
Comment choisir un fabricant avec un faible taux d'échec 3p freezer?
986Le choix d'un congélateur 3p dépend de nombreux facteurs et les utilisateurs doivent faire preuve de prudence lorsqu'ils choisissent un fabricant. Choisissez un congélateur 3p avec un faible taux de défaillance pour réduire les coûts d'exploitation. Lors de l'utilisation d'un congélateur 3p, le coût d'utilisation d'un congélateur 3p contiendra...
Voir les détails -
Instructions for use of various components of high and low temperature cycle machine
1178In the high and low temperature cycle machine, each accessory has its own performance advantages. When running, we need to have a clear understanding of each accessory in order to run the device better. The compressor functions to compress and dri...
Voir les détails