Il existe généralement trois façons de contrôler la température des réacteurs de laboratoire

1. Manual control: Manually operate the knob on the front of the reactor controller.
2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.
3. Controlled by thermostat: Silicone oil is heated through the thermostat, and the thermostat naturally has a temperature control function. Although the thermostat heating limit (usually 250°C) is not as high as that of electric heating (can be as high as 400-500°C), the thermostat rises and falls smoothly, and the low temperature can reach -60/-80°C.
Our LNEYA laboratory reactor temperature control system belongs to the third category. However, the temperature control range is from -120 degrees to 350 degrees. It adopts a fully enclosed pipeline design and a high-efficiency plate heat exchanger, which reduces the demand for heat transfer oil, improves the heat utilization rate of the system, and realizes rapid temperature rise and fall. Continuous temperature control can be achieved in the temperature range of minus 90 degrees to 195 degrees and minus 70 degrees to 220 degrees without pressure.
Jacketed glass reactors are popular in current chemical experiments. The supporting temperature control equipment has also become a matter of widespread concern in the industry. It is known that the cooling and heating temperature in the reaction process has an absolute influence on the reaction process and results. The analysis of the temperature control equipment’s ability to increase and decrease the temperature of the material has become the basic basis for choosing chiller. Then the cooling and heating capacity is not only estimated by imagination and experience, but requires scientific analysis and calculation methods, and needs to calculate the required heating power and cooling power according to the heating rate and cooling rate.
When our technicians communicate with customers, they will first understand the requirements of engineering parameters, such as high and low temperature, how long is the temperature control time, etc., so as to calculate the cooling power and heating power of the chiller required, and determine the available chiller. model, to give customers the most complete temperature control solution. If you also have this need, you can contact us.
Recommandations connexes
-
Système de refroidissement du groupe motopropulseur de la transmission avec évaporateur
999L'évaporateur est l'un des quatre principaux composants du système de réfrigération et constitue l'incarnation ultime de l'effet et de l'efficacité de la réfrigération. L'évaporateur est généralement conçu et équipé par le groupe motopropulseur de la transmission ...
Voir les détails -
How to complete the temperature control equipment for the isolation reactor?
1006The reactor is a commonly used reactor in pharmaceutical and chemical production. The isolation reactor temperature control equipment is realized by controlling two doors, namely the heating water valve and the cooling water valve. The mixing of t...
Voir les détails -
Plage de contrôle de la température et précision du testeur de température haute et basse
1058La précision de contrôle de la température de l'huile caloporteuse du testeur à haute et basse température utilisé pour tester les composants est de plus ou moins 0,5 ℃, ce qui résout le problème du décalage de contrôle de la température dans les composants électroniques. Principaux avantages...
Voir les détails -
Description of high and low temperature circulation tank refrigeration process
1395In the process of using high and low temperature circulating tanks, there may be some minor problems due to improper use, and there may be problems in the refrigeration process of Wuxi Guanya high and low temperature circulating tanks, and then we...
Voir les détails