Function of Evaporator in Air Cooled Chiller
The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water quality, and saves water resources. It is the most economical and simple machine for maintenance and repair in the current refrigeration equipment. The one-time investment of air-cooled chiller is slightly higher than that of water-cooled chiller, but the annual operation cost is lower than that of water-cooled chiller. The construction cost of machine room is the least among various cold and heat source systems, and the maintenance cost is about half of that of water-cooled chiller.

When the temperature of air or other fluid decreases, the pressure in the temperature sensing bag decreases. The valve port of the temperature control pilot valve is closed, and the refrigerant gas flow from the evaporator to the main regulating valve decreases. When the pressure at the top of the main piston is discharged into the suction pipe of the compressor, the main spring closes the main valve. In the air-cooled chiller system, when the evaporator pressure regulating valve is used to control the temperature, the temperature control pilot valve should be used to replace the pressure control pilot valve introduced earlier, so that the temperature of air or other fluids flowing through the evaporator can be accurately maintained at a predetermined value.
The evaporator is one of the four major components in the chiller system. The evaporator plays a role in heat dissipation in the chiller system. Connect the temperature control pilot valve with the joint of the outer pressure guide hole of the evaporator pressure regulating valve, and place the temperature sensing package of the pilot valve in the air flow or flowing medium to control its temperature. When the temperature of air or other medium increases, the pressure in the temperature sensing package increases, and the valve port of the temperature control pilot valve opens, so the evaporator pressure is transmitted to the space at the top of the main regulating valve piston through the outer pressure guide pipe, Press down the piston and open the main regulating valve. The evaporator pressure then drops to an appropriate value, which increases the temperature difference between air or other fluids and refrigerant, and improves the refrigeration capacity of the evaporator of the low-temperature chiller.
Recommandations connexes
-
CIPM China [C-48-2] welcomes new and old customers!
1320The 58th (Fall 2019) National Pharmaceutical Machinery & ChinaInternational Pharmaceutical Machinery Expo will be held at the Chongqing International Expo Center from November 5th to November 7th, 2019. It is recognized by the industry as prof...
Voir les détails -
LNEYA PCR microfluidic chip temperature control system project development objectivity
1058The PCR microfluidic chip temperature control system is a new dynamic refrigeration heating produced by LNEYA for the integrated circuit chip industry. For the chip testing industry, the LNEYA PCR microfluidic chip temperature control system can b...
Voir les détails -
How to deal with the equipment failure alarm of the recirculating chiller
1294Que faire en cas de panne et d'alarme pendant l'utilisation de l'équipement de refroidissement à recirculation ? Afin d'assurer la production, ces problèmes doivent être résolus rapidement. Nous devons d'abord comprendre les causes des pannes et des alarmes, et adopter dif...
Voir les détails -
Application Scope Of LNEYA Precision Chiller
1215The main application industries of LNEYA precision chiller include plastic industry, electronic industry, electroplating industry, medicine industry, food industry, vacuum coating industry and so on. These industries are the main application indus...
Voir les détails