Principle Analysis of Glycol Chiller
Glycol chiller is an industrial chiller
with glycol as refrigerant. The structure of glycol chiller is roughly the same
as that of ordinary industrial chiller, which is composed of compressor,
evaporator, condenser and electric control system. In order to ensure the
stable operation of glycol chiller, we suggest that you take explosion-proof
measures and buy explosion-proof glycol chiller as far as possible.
1、 Operation of compressor
In order to ensure that the pressure inside
the evaporator is low enough and that the refrigerant is at such a low
temperature, the compressor is used to extract the evaporated refrigerant and
compress the low temperature and low pressure into high temperature and high
pressure refrigerant gas.
2、 Use of condenser
High temperature and high pressure
refrigerant condenses into liquid in the condenser. The refrigerant in the
condenser releases heat in air or water lower than its temperature. Of course,
the temperature of air or water must be lower than that of refrigerant.
3、 How to throttle
After passing through the restrictor, the
refrigerant of the chiller drops from the condensation pressure to the
evaporation pressure, so the liquid from the condenser can be placed in the
liquid reservoir. At this time, the refrigerant is in the state of normal
temperature and high pressure, and then passes through the expansion valve to
reduce the boiling point, enters the evaporator, and the liquid absorbs heat
and evaporates.
4、 Endothermic evaporation
After passing through the restrictor, the
refrigerant liquid with low temperature and low pressure exchanges with the
evaporator, and the absorbed heat becomes saturated or superheated steam.
Recommandations connexes
-
Comment acheter un refroidisseur de laboratoire et comment l'entretenir ?
933Les refroidisseurs de laboratoire sont des produits qui fournissent des sources de froid à température constante dans l'industrie et les laboratoires. S'ils ne peuvent pas fournir une capacité de refroidissement précise, cela affectera le fonctionnement de l'équipement. Par conséquent, le refroidisseur de laboratoire doit...
Voir les détails -
High and low temperature device related instrument maintenance instructions
1129The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
Voir les détails -
Comment choisir un fabricant avec un faible taux d'échec 3p freezer?
983Le choix d'un congélateur 3p dépend de nombreux facteurs et les utilisateurs doivent faire preuve de prudence lorsqu'ils choisissent un fabricant. Choisissez un congélateur 3p avec un faible taux de défaillance pour réduire les coûts d'exploitation. Lors de l'utilisation d'un congélateur 3p, le coût d'utilisation d'un congélateur 3p contiendra...
Voir les détails -
Pourquoi les refroidisseurs d'éthylène glycol peuvent-ils être utilisés pour les réactions de polymérisation et de couplage ?
9161. Polymerization heatingGenerally, the raw materials ofpolymerization reaction are some flammable solvents, and heating up quickly maycause local temperature to be too high and cause accidents. Everypolymerization reaction has its proper react...
Voir les détails