The mechanical wear of the high temperature silicone oil cooling and heating cycle machine is an important factor that directly affects the refrigeration capacity. It is necessary to record the operating parameters during use, often listen to the sound during the operation, and check the refrigerant and refrigerating oil. Troubleshoot based on this, regular maintenance and maintenance, so that when the high-temperature silicone oil cooling and heating cycle machine fails, the maintenance personnel can quickly find the problem and eliminate the fault by referring to the recorded parameters.

Maintenance steps:
1. Discharge the refrigerant in the industrial chilled system: the needle valve is kept on the suction side of the industrial explosion-proof low-temperature refrigerator, the three-way valve is connected to the needle valve, the operating valve is opened, and the inside of the refrigerator is cooled. All reagents in the industrial refrigerator system have been discharged;
2. Replace the faulty parts of the high-temperature silicone oil cooling and heating cycle machine: If you know which parts are faulty, please directly replace the faulty parts;
3. Nitrogen flushing and pressure test: Nitrogen is still injected through the needle valve on the suction side of the industrial high-temperature silicon oil cooling and heating cycle machine;
4. Vacuum: After the pressure test, the industrial refrigerator needs to be vacuum cleaned to ensure that there is no problem;
5. Refrigerant filling: There are two filling methods for the refrigerant in the high-temperature cooling and heating cycle machine, namely the low-pressure side filling method and the high-pressure side filling method;
6. Test run: After completing the above steps, please test run the high-temperature silicone oil cooling and heating cycle machine to ensure that there is no problem;
After completing the maintenance of the high-temperature silicone oil cooling and heating cycle machine and troubleshooting, the performance of the corresponding parts will be tested to ensure the reliable and stable operation of the equipment.
Recommandations connexes
-
How to clean LNEYA low temperature refrigerator?
1112LNEYA low temperature refrigerators need to be cleaned after a long time of use. So, how should the cleaning be carried out? How to clean it is not wrong? The low-temperature refrigerator cleaning includes the cleaning of the cooling water system ...
Voir les détails -
Description du système de contrôle de la température de chauffage et de refroidissement SUNDI de qualité industrielle
1319Le système de contrôle de la température de chauffage et de refroidissement de qualité industrielle de la série SUNDI est un dispositif développé et fabriqué par LNEYA en utilisant ses propres avantages dans le domaine du refroidissement, du chauffage et du contrôle de la température, et propose des services personnalisés...
Voir les détails -
Semiconductor refrigeration temperature control table cooler operation instructions
1191The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching bet...
Voir les détails -
Performance de l'enceinte d'essai à haute et basse température
13021. Il dispose d'une large plage de contrôle de la température, qui peut répondre aux besoins des utilisateurs.2. avec une méthode unique de contrôle équilibré de la température, avec une capacité de chauffage stable et équilibrée, un contrôle de la température de haute précision et très stable peut être effectué;Le ...
Voir les détails