What are the influences on the refrigeration factors of the enclosed explosion-proof chiller?
Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when purchasing the enclosed explosion-proof chiller. The cooling capacity and other parameters are provided to the chiller manufacturer, and professionals will select the model for you to achieve the required cooling effect.
The enclosed explosion-proof chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor and indirectly affects the cooling effect. There is leakage or shortage of refrigerant in the enclosed explosion-proof chiller, which leads to a decline in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.

The dust in the condenser of the enclosed explosion-proof chiller will affect the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor cooling performance of the enclosed explosion-proof chiller. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and starts to evaporate. After the compressor is compressed and throttled by the expansion valve, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the cooling effect.
When the filter of the enclosed explosion-proof chiller is blocked, it affects the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It needs to be checked regularly and cleaned. When the filter is seriously clogged, it is recommended to replace the new filter drier.
Recommandations connexes
-
The Phenomenon of Ice Jam in Low Temperature Chiller System
860The phenomenon of ice jam in low temperature chiller system is mainly due to the excessive water in the refrigeration system. With the continuous circulation of refrigerants, the water in the refrigeration system gradually concentrates at the outl...
Voir les détails -
Four Key Points of Water Cooled Chiller Installation
1128The installation of water-cooled chiller can be carried out from four aspects: first, the installation of chiller, then the installation of water pipe, water pipe cleaning and equipment insulation. Do not underestimate the installation of this par...
Voir les détails -
New energy power car power battery detection system vacuum description
1121The new energy power vehicle power battery test checks the vacuum pump switch in the closed state before operation; when the vacuum pump is placed horizontally, ensure that the lubricating oil and the oil level line are kept horizontal; whether th...
Voir les détails -
Professional introduction of dynamometer with motor cooling device
1262In the test of AC and DC motor and power tool, the test equipment such as dynamometer is often used. The dynamometer mainly tests the torque, speed and output power of the motor. The speed of the dynamometer usually Professional introduction of d...
Voir les détails