Application pratique de différents compresseurs dans l'industrie du froid industriel
In the current refrigeration industry, the efficiency of the equipment is closely related to temperature. LNEYA tells you that the efficiency of the refrigeration equipment required under control has been improved. Then, the selection of the compressor is very important in different situations.
Classification of chiller compressors:
Screw chiller compressors are all volumetric refrigeration compressors, which can be divided into reciprocating compressors and rotary compressors. The reciprocating compressor uses a piston, a crank, a link mechanism or a piston, a crank, and a slide tube mechanism, and the rotary compressor uses a shaft crank mechanism.
Industrial chillers can be divided into low-temperature, medium-low temperature and ultra-low temperature compressors according to the scope of application.
Low-temperature compressor (evaporation temperature -35 ~ -15 ° C), generally used in food freezer and so on.
Medium and low temperature compressor (evaporation temperature -20 ~ 0 ° C), generally used in refrigerators and so on.
Ultra-low temperature compressor (evaporation temperature -5 to 15 °C), generally used in dehumidifiers, heat pumps, etc.
Application of chiller compressor:
Piston compressors are qualified for a long time and are used in many places such as cold storage.
Rotary compressors are mainly used in refrigeration units as well.
Scroll compressors are mainly used in low temperature equipment and refrigeration units.
Screw compressors are mainly used for cooling capacity, and are used in cold storage and chillers.
Centrifugal compressors have a higher cooling capacity. Generally used in chillers.
With the above sharing, do you know how to choose? LNEYA’s refrigeration equipment is imported branded compressors, you can rest assured when you buy!
Recommandations connexes
-
The Instruction Of Ultra Low Temperature Freezer Minus 80 Degrees
1202The machine must be tested before usage (or before it is energized again) in the following conditions: when ultra low temperature freezer is first used in ultra low temperature freezer minus 80 degrees, or after the ultra low temperature freezer i...
Voir les détails -
Méthode de dépannage pour le dispositif de réfrigération d'une bouilloire de réaction chimique refroidie par air
978Si l'air pénètre dans le système de réfrigération du refroidisseur à air de la bouilloire de réaction chimique, les conséquences seront nombreuses. Si l'air pénètre d'abord dans le système de circulation d'air, la pression augmentera, l'effet de dissipation de la chaleur du condenseur sera également...
Voir les détails -
-
Comment choisir un refroidisseur d'eau déionisée de laboratoire ?
1176L'eau pure fait généralement référence à l'eau qui a été traitée pour éliminer les impuretés, les ions, les matières organiques, etc. Les exemples les plus courants sont l'eau distillée, l'eau obtenue par osmose inverse et l'eau déionisée. L'eau déionisée a une faible conductivité en raison de son...
Voir les détails