Questions relatives à l'entretien de la chambre à basse température
2.The temperature and humidity of the low temperature chamber are the important factors affecting the performance of the instrument. It can cause the corrosion of mechanical parts, reduce the smoothness of metal mirror, and cause the error or performance degradation of mechanical parts of high and low temperature test box. The corrosion of optical components such as gratings, mirrors and focusing mirrors in high and low temperature test boxes results in insufficient light energy, stray light, noise, etc. Even the instruments stop working, thus affecting the life of high and low temperature test boxes, which should be regularly corrected during maintenance.
3. A certain amount of dust will accumulate inside the low temperature chamber after a certain period of use. It is better for the cryogenic testing machine to open the outer cover of the high and low temperature testing box periodically under the guidance of the maintenance engineer or engineer for dust removal. At the same time, the radiators of each heating element are re-tightened to clean the sealing window of the optical box. If necessary, it should be calibrated to clean and lubricate the mechanical part. Finally, it should be restored to its original state and some necessary tests, adjustments and records should be made.

Recommandations connexes
-
-45 °C freezer manufacturers analyze compressor burnout detection and repair methods
963In the -45 ° C freezer, the compressor is one of the more important components, the manufacturer Wuxi Guanya (LNEYA) tells everyone that once the compressor fails, it needs timely inspection and maintenance, then how to check the work and maintena...
Voir les détails -
Quelles sont les industries qui utilisent les équipements de test des dispositifs à semi-conducteur ?
1174Semiconductor device test equipment is used more in the semiconductor industry. So, how much do you know about the applicable semiconductor conductors? The properties of this substance are still recommended to the user. In general, substances can ...
Voir les détails -
How to solve the problem of refrigeration pump circulator pump failure?
1098Cooling heating devices are required in many chemical pharmaceutical and laboratory applications. Then how to solve the failure of the refrigeration heating device is also concerned about how to solve it? 1. Circulating pump failure The circulatin...
Voir les détails -
Application of jacketed reactor cooling and heating circulator in chemical reactions
1046jacketed reactor cooling and heating system application
Voir les détails