Thermal oil heating system installation and fault analysis
Lorsque le heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil heating system device.
The faults of the heat transfer oil heating system device can be roughly divided into two categories: mechanical fault and system fault. Mechanical fault refers to the detachment and damage of the heating device, fuel blockage, circulation pump, valve leakage, etc. are collectively referred to as mechanical faults, and mechanical faults can pass through small and medium Overhaul to solve.
Heat transfer oil heating system device system failure needs to pay attention to whether the heat transfer oil heating system device is designed reasonably, install and use the standard heating system. After the heat transfer oil is operated for a period of time under high temperature conditions, a series of changes are inevitable. For example, the viscosity increases, the residual carbon increases, etc., which causes the system to have abnormal pressure and difficulty in heating. If it cannot be solved in time and effectively, the situation will deteriorate rapidly. The reason is that the heat transfer oil will be in the furnace after carbonization. The inner surface of the tube forms coking, and the formation of the coke layer will intensify the carbonization speed of the oil film. Such a vicious cycle will not only quickly scrap the oil, but also cause high temperature oxidation and peeling of the outer surface of the tube, and the tube wall becomes thinner and thinner. “.

In addition, a considerable part is an irregular heating system. In some systems, the heating furnace is self-made or modified; some systems lack the necessary accessories such as circulation pump and expansion tank, and some models and sizes are unreasonable. The problem of electric heating system is even more serious. The service life of heat transfer oil is short, and frequent system failure is a common problem. Therefore, it is very important to choose a regular heat conduction oil heating system device manufacturer.
The related faults of the heat transfer oil heating system device need to be solved in a timely and effective manner at the beginning of the occurrence, so as to avoid the improper disposal of the heat transfer oil heating system device.
(Cet article provient du réseau source. En cas d'infraction, veuillez contacter le LNEYA pour suppression, merci).
Recommandations connexes
-
How to complete the temperature control equipment for the isolation reactor?
1002The reactor is a commonly used reactor in pharmaceutical and chemical production. The isolation reactor temperature control equipment is realized by controlling two doors, namely the heating water valve and the cooling water valve. The mixing of t...
Voir les détails -
Precautions for operation of ethylene glycol utra-low temperature chiller at minus 30 degrees
1062The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly,...
Voir les détails -
Application area of high temperature refrigeration and cooling control system
891The high-temperature refrigeration and cooling control system is used for supporting glass reactors, rotary evaporators, fermentation tanks, and calorimeters; widely used in petroleum, chemical, metallurgical, biochemical, physics, testing and che...
Voir les détails -
Application à l'industrie chimique pharmaceutique - Contrôle de la température du réacteur de chauffage
1164The pharmaceutical chemical industry involves many chemical reactions. The traditional heating reactor temperature control work efficiency is relatively low, the production cost is relatively high, and the device is relatively cumbersome. To this ...
Voir les détails