Comment traiter les fuites de réfrigérant lors du traitement des déchets organiques ?
Au cours du processus de traitement des gaz résiduaires organiques, s'il est constaté que le réfrigérant fuit, il est recommandé de le traiter à temps. Le fabricant professionnel de traitement des gaz résiduaires organiques LNEYA analyse ensuite les connaissances en matière de traitement des gaz résiduaires organiques...
Organic waste gas treatment VOCS gas single material or multi-material condensation recovery, the main treatment gases are: hydrocarbons such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, Styrene, naphtha, etc.; alcohols, ethers, ketones, esters, etc., in the event of a situation, we must now fill the leak or treatment of the refrigerant leakage, then replace the desiccant, re-vacuum treatment, Fill the appropriate refrigerant. When you find that the leaking refrigerant is partially immersed in water, stop the chiller and quickly remove the water from the tank to prevent the compressor from drawing water into the system for more serious damage.

So, what should be done if the organic waste gas treatment refrigerant is found to be insufficient? Organic waste gas treatment failure phenomenon: the whole vehicle refrigeration effect is poor, the air outlet air is only cool, and the manifold pressure gauge check finds that the high pressure is cut and the low pressure side pressure is low (when the compressor speed is 2000/mim, the ambient temperature is about 35C). The low pressure gauge index is lower than 1kg/CM square, the high pressure gauge index is lower than 10kg/CM square, and the bubble flow is visible from the sight glass.
This may be due to a refrigerant leak point in the refrigeration system, resulting in insufficient refrigerant. Treatment method Use an electronic leak detector to detect the leak point and carry out the replacement or replacement of parts. If the parts are not replaced, only the appropriate amount of refrigerant can be replenished; if the parts are replaced, the appropriate amount of refrigerating oil should be added as required, and the refrigerant should be added after the system is vacuumed.
The above is the relevant treatment of organic waste gas treatment refrigerant leakage. If the Wuxi LNEYA organic waste gas treatment equipment fails, it is recommended to solve it in time!
Recommandations connexes
-
Advantages and disadvantages of water-cooled chillers
1105The water-cooled industrial chillers produced by LNEYA are refrigeration equipment that provides chilled water. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers. Water-cooled chiller configuration: 1....
Voir les détails -
Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
1185The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil l...
Voir les détails -
Description des caractéristiques du dissipateur thermique dans le contrôle de la température des puces
1318Avec le développement continu des puces électroniques, la technologie de dissipation de la chaleur progresse également. La technologie de contrôle de la température des puces de LNEYA est continuellement promue en même temps que l'équipement de test des puces. La tendance de développement des puces électroniques modernes...
Voir les détails -
Specific operation analysis How to dehumidify when using industrial freezer
1236In the process of using industrial freezers, there may be some moisture in the refrigeration system. Therefore, the dehumidification of industrial freezers is very important, so how to dehumidify? When dehumidifying, users who purchase industrial ...
Voir les détails