Maintenance of vacuum pump for fully enclosed heating and cooling circulator
Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump?
For the fully enclosed heating and cooling circulator circuit, the electronic circuit and the mechanical rotating part are routinely inspected and repaired. Pay attention to whether the various indicators are damaged or deteriorated, and regular maintenance is required.

Do the vacuum pump working status and the registration of each working time, record the cause of the instrument failure and the troubleshooting method in time to ensure that the vacuum pump works in a better state.
Keep the vacuum pump symmetrically balanced. If the sample tube placed in the pump chamber is unbalanced, it will cause the circulating water vacuum pump to shift. After the shutdown is reset, check if the vacuum pump is normal.
Before use, please pay attention to check the rotor for corrosion points and fine cracks. The rotor that has been corroded or cracked is forbidden to use. If the rotor exceeds the shelf life, it should be checked frequently to ensure personal safety.
The fully enclosed heating and cooling circulator vacuum pump cover door bolts should be checked frequently and kept flexible to prevent forced opening or closing. When an abnormality occurs, it is necessary to repair and replace it in time. Common faults, usually pay attention to observation, and promptly eliminate the solution.
After use, the water in the pump chamber should be dried, and a small amount of neutral grease should be applied to the cone surface of the motor shaft periodically. Remove the rotor from the circulating water vacuum pump for a long time, wipe it clean and place it in a dry place.
LNEYA specializes in the production of fully enclosed heating and cooling circulators, refrigeration and heating circulators, TCU, ultra-low temperature freezer, freezer and other equipment of good quality, laughing and welcoming visitors come to negotiate!
Recommandations connexes
-
Exigences relatives à l'installation d'un refroidisseur à glycol
1162En été, l'utilisation de refroidisseurs au glycol est relativement fréquente. Des refroidisseurs de glycol efficaces sont également nécessaires. Par conséquent, lors de l'installation des refroidisseurs de glycol, ils doivent être installés sur un sol lisse et propre. Pourquoi choisir un sol lisse lors de l'instal...
Voir les détails -
Attention points for the use of laboratory chiller manufacturers’ equipment
913In the laboratory, a wide range ofexperimental instruments are widely used. When the experimental instruments arein operation, they are inseparable from the high-low temperature circulatingdevice refrigeration heating equipment. What should be ...
Voir les détails -
Description des défauts communs des unités de réfrigération à semi-conducteurs LNEYA
1410Si une alarme de haute tension se produit dans l'unité de réfrigération des semi-conducteurs, il est nécessaire de vérifier si la tuyauterie externe est bloquée ou sale. Nettoyez et retirez à temps. S'il s'agit d'un dispositif de réfrigération à semi-conducteur refroidi par air, il est nécessaire ...
Voir les détails -
Compressor Inspection And Routine Maintenance Of Small Water Cooled Chillers
1072When people are hungry, they have to eat, and when the machine is broken, of course, it has to be repaired. In daily use, small water cooled chiller requires regular maintenance and other operations. Today, I would like to share with you how to ju...
Voir les détails