Connaissances en matière d'entretien des dispositifs de circulation à température constante à haute et basse température
The high and low temperature constant temperature circulation device is one of the more common equipments in the temperature control system. A good equipment is inseparable from daily maintenance. So how much do you know about maintenance?
High and low temperature constant temperature circulation device The entire liquid circulation is closed, with an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, but are mechanically connected, regardless of whether the temperature of the liquid circulation is high temperature or low temperature expansion in the container The medium is below 60 degrees.
High and low temperature constant temperature circulation device, no water vapor absorption at low temperature, no oil mist at high temperature, heat transfer oil can have a wide working temperature; mechanical and electronic valves are not used in the whole circulation system. When opening or closing the test object from the box, the article shall not be in contact with the door sealing strip. If the compressor is cooled by air cooling, the condenser fan shall be regularly inspected and the condenser shall be decontaminated and dedusted.

Due to the different cleanliness levels of the high and low temperature constant temperature circulation device, many small particles such as dust will be condensed on the evaporator under the forced air circulation, so we must clean the evaporator regularly. The humidifier fouling easily causes the humidifier to dry and may burn the humidifier, so the water circuit and the humidifier must be cleaned regularly. At the end of each experiment, it is recommended to clean the test chamber with clean water to keep the equipment clean. After the cabinet is cleaned, the cabinet should be dried to keep the cabinet dry. After the completion of each test, the temperature is set near the ambient temperature, and the power is turned off after about 30 minutes of work, and the wall of the working chamber is wiped clean.
LNEYA high and low temperature constant temperature circulation equipment professional manufacturer, producing various types of high and low temperature one machine, can also design and manufacture various non-standard products according to customer needs.
Recommandations connexes
-
What are the effects of oil level and oil difference in low temperature chillers?
1248LNEYA tells you that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil storage and special oil cooler. Oil level It refers to the level of the lubricant in the oil storage container. Th...
Voir les détails -
Comment résoudre le problème de givrage du dispositif de circulation à basse température ?
1358The failure of the low temperature circulation device frosting is mainly because the compressor return air temperature is too low, which may be that the throttle valve liquid refrigerant supply is in a normal state in the low temperature circulati...
Voir les détails -
Main points of maintenance of flash high and low temperature test chiller
985Buyers of flash high and low temperature test chiller are increasing day by day. Many people find that the service life is greatly reduced after purchasing. Therefore, operation management and maintenance personnel must have certain professional k...
Voir les détails -