How to replace the scroll compressor of the impact tester model?
In terms of different impact tester models, the configuration is also somewhat different. Among them, special care should be taken when replacing the scroll is a compressor. If the replacement is not noticed, the impact tester cannot be used.
The prohibition of the impact tester is only carried out from the high pressure side when the scroll compressor is replaced. If it is only carried out from the high pressure side, the axial seal of the scroll will cause the refrigerant to remain on the low pressure side. This is to carry out the simultaneous discharge of the high-pressure side and the low-pressure side when the refrigerant is discharged, and when the maintenance impact tester replaces the scroll compressor. Things to be aware of. When repairing the impact tester welding operation, sufficient nitrogen gas is introduced into the equipment to prevent the formation of an oxide film on the inner wall of the copper pipe (the time for nitrogen to pass is sufficient). To check the nitrogen content, a ignited scent or cigarette can be placed at the other inlet of the nitrogen. If the scent is extinguished, the air in the system is emptied and the welding operation can be performed.

In order to prevent the impact tester from burning the compressor during the test, a vacuum pump must be used to evacuate. Moreover, it is forbidden to use the compressor as a vacuum pump to evacuate the air in the external pipe when replacing the compressor or other parts. The maintenance impact tester has higher requirements due to the use of the scroll compressor. Reminder: When the maintenance impact tester system is in the maintenance, it is forbidden to reduce the pressure in the system to a vacuum state. Only the pressure in the system can be cooked above the gauge pressure of 0.03MP, otherwise the compressor will draw the side vortex. The axial seal of the disc forms a vacuum, which can damage the compressor if not handled properly.
The difference between the compressors of different impact tester models is definitely present. If the operator cannot replace them completely, it is recommended to contact the manufacturer for replacement.
Recommandations connexes
-
Comment fonctionnent les refroidisseurs CVD et PVD pour semi-conducteurs ?
1069Le principe de fonctionnement des refroidisseurs utilisés dans les processus de dépôt chimique en phase vapeur (CVD) et de dépôt physique en phase vapeur (PVD) des semi-conducteurs consiste principalement à éliminer la chaleur générée pendant le processus en faisant circuler de l'eau de refroidissement ou des...
Voir les détails -
High-low temperature control system with different configurations of high-pressure reactors
834Different configurations of high pressure reactors, the quality of products brought by different manufacturers is not the same, but the points of attention are the same, you need to pay attention to it. 1. To be used at the designated location and...
Voir les détails -
What are the applications of steam circulators in chemical industry?
989The steam circulator in the chemical industry is a temperature control equipment in the pharmaceutical and chemical industry. When users operate, they need to understand the performance and maintenance knowledge in order to operate the equipment e...
Voir les détails -
Précautions à prendre pour l'utilisation d'un système antidéflagrant de régulation de la température par réfrigération et chauffage à fluide unique
1030There are many types of reactors, and laboratory reactors are one of them. What is the point of attention of LNEYA reactor temperature control system-explosion-proof single-fluid refrigeration heating temperature control device? The temperature me...
Voir les détails