Comment choisir l'équipement du réacteur ?
The choice of equipment for the reactor needs to be measured by the following points:
1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between.
2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 degrees, equipped with a cooling machine; there is also an oil cooling, suitable for high temperature resin, but the temperature should be greater than or equal to 200 degrees.
3. Material: Generally, there are SUS304 stainless steel, Q235 carbon steel, SUS316 stainless steel, etc.;
4. Stirring method: inclined blade type with inclined angle of 45-60 degrees; anchor type with scraping edge scraping; dispersing disc type with 1000/1500/2800 rpm for shearing (for paint or powder, Hot melt adhesive (rubber); and ribbon type for high viscosity with dispersing disc (for hot melt adhesive)
5. Sealing form: generally has mechanical seal, packing seal, double sealing surface, single sealing surface;
6. Structural aspects: generally have outer half tube type (more than or equal to 2 tons); outer jacket type (more than 3 tons); inner coil; no jacket (no heating); inner coil type (suitable for small viscosity, Small fluidity)).
7. The structure of the kettle body: determined according to size, material and thickness;

Wuxi Guanya LNEYA refrigeration heating temperature control system is the first choice for the reactor equipment, ultra-high temperature cooling technology, can directly cool down from 300 degrees high temperature. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
Recommandations connexes
-
Application Scope Of LNEYA Precision Chiller
1212The main application industries of LNEYA precision chiller include plastic industry, electronic industry, electroplating industry, medicine industry, food industry, vacuum coating industry and so on. These industries are the main application indus...
Voir les détails -
16. – 18. June 2020 | The Automotive Testing Expo Europe-LNEYA
1413The Automotive Testing Expo Europe is a trade fair for automotive test, evaluation and quality engineering. It is one of the most important event of its kind in Europe.The fair widtmet the latest technologies and services to improve quality, safet...
Voir les détails -
Comment gérer l'alarme de défaillance de l'équipement du refroidisseur à recirculation ?
933Que faire en cas de panne et d'alarme pendant l'utilisation de l'équipement de refroidissement à recirculation ? Afin d'assurer la production, ces problèmes doivent être résolus rapidement. Nous devons d'abord comprendre les causes des pannes et des alarmes, et adopter dif...
Voir les détails -
Comment maintenir le système de refroidissement à température constante à haute et basse température ?
960Le système de refroidissement à température constante à haute et basse température effectue des opérations de réfrigération et de chauffage dans l'industrie pharmaceutique et chimique. Il suit des règles de fonctionnement et des exigences méticuleuses pour améliorer continuellement sa qu...
Voir les détails