The reason why the cooling water circulator needs the main water circulation
The supplement of the water cycle is directed to a water-cooled cooling water circulator, and the air-cooled cooling water circulator does not have this problem. The water-cooled cooling water circulator needs cooling water during normal operation. The cooling circulating water is the most important part of the whole water-cooled cooling water circulator. However, the water-cooling system of the water-cooled cooling water circulator is in the process of normal operation. What is the main reason for the cooling water consumption of the water-cooled cooling water circulator?
Drifting and other issues:
The cooling water circulator cooling water may be sprayed by the water purifier, the fan’s air blower, and the filler in the cooling tower. In these processes, there may be problems of drifting and splashing, and certain measures may be taken at a certain To the extent that these problems are avoided, they cannot be avoided. Therefore, problems such as drifting water are also an important cause of cooling water consumption.
Loss, leakage:
In general, each of the water-cooled cooling water circulators and the pipes and valves that come into contact with the cooling circulating water are not necessarily able to avoid leakage and loss. Small amounts and traces of leakage are allowed. Of course, this is also the water-cooled cooling water circulation. The cooling water of the unit must be replenished frequently.
Natural loss and consumption during operation:
During the normal operation of the water-cooled cooling water circulator, there will be some loss and consumption. Basically, it will be reduced by running in the water pipeline. As long as it is in normal operation, there will be some reduction, loss and consumption.
Evaporation during operation:
This is a relatively large amount of water consumption point. During the operation, it is inevitable that the cooling circulating water will be exposed to higher temperatures and evaporate.

The reason for the consumption of cooling water is that the cooling water circulator must be actively and adequately replenished. If it cannot be replenished in time and in sufficient quantities, the cooling water circulator will not operate properly.
Recommandations connexes
-
L'application du congélateur à plaques froides
1046Le système de réfrigération du congélateur à plaques froides adopte la technologie du super-refroidissement secondaire avec une réfrigération rapide et une température limite basse. Il utilise des compresseurs à piston semi-hermétiques de marque importée, des compresseurs composés à piston semi-hermétiques...
Voir les détails -
New energy power car power battery detection system vacuum description
1121The new energy power vehicle power battery test checks the vacuum pump switch in the closed state before operation; when the vacuum pump is placed horizontally, ensure that the lubricating oil and the oil level line are kept horizontal; whether th...
Voir les détails -
Étapes de débogage d'un refroidisseur d'eau industriel dans l'industrie chimique
906Après avoir terminé l'installation des refroidisseurs d'eau industriels dans les entreprises chimiques, il est nécessaire de procéder à un certain débogage au début de la phase d'exploitation. Ce n'est qu'en procédant à un débogage minutieux que nous pouvons...
Voir les détails -
Which part of the chip testing system requires high and low temperature control?
818In the chip testing system, the environmental control equipment requires high and low temperature control. Specifically, this section mainly includes the following two key devices: 2. Temperature control system: For certain testing app...
Voir les détails