Cooling system of liquid-cooled energy storage cabinet-chiller
With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaic, and electric energy stations has increased. If the temperature of the energy storage battery pack is not well controlled, the temperature of the battery will be unstable, leading to an increased risk of short circuit and damage to surrounding components.
The containerized energy storage system is mainly composed of a containerized machine room, a battery management system, and a battery pack temperature control system. Therefore, the cooling system of the special containerized energy storage system is becoming more and more high-performance and highly stable. The temperature control system includes chillers, chiller pipes, air conditioners, and air ducts. Provide suitable and stable ambient temperature for the overall container energy storage system.
During the work of the containerized energy storage system, the lithium battery system, battery management system, energy storage monitoring and other systems will generate a lot of heat due to current changes. In order to ensure the efficient operation of the energy storage system at all times, some systems will be equipped with dedicated energy storage system cooling units , The cooling method is divided into two types: air-cooled and water-cooled.
LNEYA’s energy storage integrated cabinet cooling system follows a compact design and can be an external cooling system for the battery pack energy storage integrated cabinet. Efficient nanny-style thermal management system is suitable for applications where the battery inside the energy storage container generates a lot of heat and is sensitive to ambient temperature. Integrate upper computer communication, alarm and other functions, without complicated debugging.
Liquid cooling is integrated into each battery cabinet using glycol antifreeze. The system is fully enclosed design, supports dual system cooling circuits, mutual backup to avoid battery shutdown and safety failure; intelligent, multi-language color touch screen, provides clear and comprehensive important data information, and can display flow pressure data in real time; liquid cooling system IP50 The above protection can meet the anti-corrosion requirements, and can be used below 3000 meters above sea level. The temperature setting range is -45°C~55°C, and the liquid temperature can be precisely controlled within ±0.5°C.


Recommandations connexes
-
Refroidisseur de liquide(Commercial Energy Storage) (en anglais)
2377Battery Energy Storage Systems are filled with many battery cells, generating a large amount of extreme heat load. This means that the cooling system needs to precisely control the temperature and efficiently dissipate the l...
Voir les détails -
Refroidisseur à liquide(Energy Storage) (stockage d'énergie)
3269Model CNYL -45~55 Cooling Capacity 45KW Temperature Control Accuracy ±0.5℃ Real-time temperature record Secondary Refrigerant Ethylene glycol antifreeze, fully enclosed design of refrigerant circulation system Refrigerant R41...
Voir les détails -
Refroidisseur de liquide(Charging Pile)
2319Modèle CHDYL-4 -45℃~55℃ Puissance de refroidissement 4KW Précision du contrôle de la température ±1℃ Enregistrement de la température en temps réel Réfrigérant Système de circulation de saumure entièrement fermé Débit 1.8~5.5L/min Pression 0.7bar Température minimale d'entrée de l'eau 15°C ...
Voir les détails -
Équipement de test de batterie de voiture à énergie nouvelle pour la description de la batterie
986Lead-acid battery raw materials are easy to obtain, the price is relatively low, the high rate discharge performance is good, the temperature performance is good, can work in the environment of -40~+60 °C, suitable for float charging, long service...
Voir les détails -
Méthode d'entretien du réfrigérateur ultra-basse température de moins 17°C
1051Après une utilisation prolongée du réfrigérateur ultra-basse température de moins 17 °C, il est nécessaire d'effectuer certains travaux d'entretien. Si l'utilisateur ne sait pas comment effectuer les travaux d'entretien, vous pouvez contacter le fabricant pour obtenir les...
Voir les détails -
Maintenance of Glycol Cooling Heating Control System
2066Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control System are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, LNEYA Ref...
Voir les détails -
The difference between direct contact liquid cooling and cold plate liquid cooling technology
1263The cold plate liquid cooling technology is an implementation method in which the heat of the heating components is indirectly transferred to the cooling liquid enclosed in the circulating pipeline through the cold plate, and the heat is...
Voir les détails