LNEYA data center liquid cooling solutionLiquid Cooled CDU Distribution Unit
Cold plate liquid cooling CDU-15kW
LNEYA relies on its strong R&D, construction, and operation and maintenance capabilities in the field of data centers to launch a cold-plate liquid-cooled CDU with a new air-liquid architecture. Building construction and renovation of old machine rooms, with excellent PUE indicators throughout the year, green, energy-saving, safe and reliable operation.

Applications: Renovation of small and medium-sized old data center
Energy saving, high efficiency and superior performance
Air-liquid structure, heat dissipation up to 12KW, green and energy-saving, system PUE≤1.2
Standard plug-in design, flexible layout, height is only 5U. Improve the rate of cabinets in the computer room
Front, side inlet, rear outlet air duct design, optimized airflow organization, cold and hot aisle isolation
Easy to install and easy to maintain
Does not involve the primary side pipeline layout, reducing the risk of pipeline laying, engineering quantity and water entering the machine room
Modular design, highly integrated products, easy installation, easy maintenance interface, standard quick connection, two-way cut-off of the flow channel, direct plug-in and maintenance of the pipeline on site
Renovation is simple. The old computer room can rely on the existing refrigeration system, only
Intelligent optimization of remote operation
System status analysis, real-time regulation of refrigerant flow, flow velocity and air volume, load balancing
Liquid product touch screen on-site and host computer remote centralized monitoring, human-computer interaction
Friendly interface
Anti-condensation control, liquid leakage detection, enhanced anti-interference design, high stability Support Modbus-RTUTCPMP communication
Safe and reliable system stability
Double-pump 2N redundant frequency conversion design, automatic switching in case of failure; when the two pumps are running at the same time, overclocking can increase the heat transfer by about 10%
Low-noise dual-fan design, when a single fan fails, the entire liquid cooling system will not stop
Expansion tank for pressure stabilization, full-scale group system design, leakage concealment reduction
High-efficiency pure copper micro-channel heat exchanger, highly compatible with pure steel liquid cold plate, improving system reliability
Introduction to cold plate liquid cooling system products and equipment
Introduction to cold plate liquid cooling chiller
chargement...
已经是到最后一篇内容了!
Consultation gratuite 7 * 24 et solutions complètes


Courriel : sales@cnzlj.com
WhatsApp : 086 13912479193
Recommandations connexes
-
Introduction to cold plate liquid cooling system products and equipment
1128Introduction to cold plate liquid cooling chiller
Voir les détails -
Immersion phase change liquid cooling system
1156What is immersion phase change liquid cooling system?
Voir les détails -
Heat transfer oil cleaning instructions in the heat transfer oil secondary circulation system
1094The heat transfer oil secondary circulation system uses the heat transfer oil as the medium to carry out the refrigeration and heating temperature control. Then, when the user cleans the heat transfer oil in the heat transfer oil secondary circula...
Voir les détails -
Cold and hot one mold temperature machine maintenance method description
1236In the process of using the hot and cold integrated mold temperature machine, it is necessary to carry out regular maintenance and repair. Then, LNEYA will share with you the maintenance method of the hot and cold integrated mold temperature machi...
Voir les détails -
How to choose the pipeline for condensing adsorption recovery vocs?
955Condensate adsorption recovery vocs device at the time of selection, its system configuration needs to be clear to be able to buy with confidence, then, the condensation adsorption recovery vocs pipeline attention points, how to choose? Condensate...
Voir les détails -
Comment juger de l'état de fonctionnement du système de contrôle de la température constante des produits chimiques et pharmaceutiques ?
952De nos jours, de nombreuses industries pharmaceutiques et chimiques utilisent le système de contrôle de la température constante de LNEYA. Comment juger de son état de fonctionnement pendant l'opération ? Il ne doit pas y avoir de bruit dans le cylindre du système de contrôle thermostatique des produits chimiques et pharmaceutiques...
Voir les détails
Soumettre à consultation
Nous vous répondrons dans les 24 heures