- Cooling capacity @20℃3kW~87kW
- RéfrigérantR407C
- Lieu d'origineChine
Il convient à l'objet de régulation de la température cible qui dispose déjà d'un réservoir de stockage du froid et d'une pompe de circulation. Le fluide est transporté vers le groupe frigorifique de la série LTZ M par l'intermédiaire de la pompe de circulation, qui est un...

WhatsApp : 086 13912479193

WeChat 86 15152266993
Industry temperature control solutions
LTZ variable frequency chiller
The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user’s cooling and heating load requirements through the built-in frequency conversion device. The variable frequency unit adopts advanced frequency conversion technology to accurately control the compression and fan operating speed.
DETAIL ADVANTAGE,STRIVING FOR EXCELLENCE

Paramètres
Modèle | LTZ-1 M | LTZ-3M | LTZ-6M | LTZ-15M | LTZ-25WM |
LTZ-3WM | LTZ-6WM | LTZ-15WM | |||
Plage de température | 5 ℃~30℃ (Use ethylene glycol water solution below 10℃) | ||||
Précision du contrôle de la température | ±0.5℃ | ||||
Retour d'information sur la température | Pt100 | ||||
Cooling capacity at 20℃ | 3kW | 10,5 kW | 21kW | 52kW | 87kW |
Compresseur | Mitsubishi, Hitachi | Variable frequency compressor | |||
Méthode d'étranglement | Soupape d'expansion thermique | Soupape d'expansion électronique | |||
DI heat exchanger | Échangeur de chaleur à plaques | ||||
Input, display | 4.3-inch touch screen | 7-inch color touch screen\ PLC controller | |||
Communication | Modbus RTU protocol RS485 interface | ||||
Protection de la sécurité | It has self-diagnosis function; refrigerator overload protection; high and low voltage protection, overload relay, thermal protection device, exhaust and suction temperature protection, sensor fault protection and other safety protection functions.。 | ||||
Réfrigérant | R407C | ||||
Taille de l'interface | G1/2 | G3/4 | G3/4 | ||
Water-cooled type @20℃ | 600L/H | 1800L/H | 3600L/H | 9000L/H | 15000L/H |
G3/4 | G1 | DN32 PN10 | DN40 PN10 | ||
Condenseur refroidi à l'eau | The condenser of the water-cooled equipment uses a plate heat exchanger and requires a closed cooling tower for water supply | ||||
Condenseur refroidi par air | Échangeur de chaleur à microcanaux | ||||
Alimentation électrique | 380V 50HZ can choose three-phase 220V 460V | ||||
Contact pipe material | SUS304 | ||||
Matériau de l'enveloppe | Cold rolled plate sprayed (REL7035) |
WIND COLD WATER COLD ON DEMAND SELECTION

The circulating fluid from the pump is cooled by the customer’s equipment and then returns to the thermostat. The circulating fluid passes through the refrigeration circuit, reaches the set temperature, and is then output to the customer’s device side through the thermostat.
CASCADECOMMUNICATION TÉLÉOPÉRATION

According to the serial communication remote control signal input and output, one of the contact inputs can be remotely operated using serial communication for remote operation, and the other is used to monitor the flow through the flow switch and read the alarm output.
Alarm, operating status (start, stop, etc.)
Signal output
The alarm and status inside the temperature controller can be divided into 3 output signals according to their content.