Comment résoudre le phénomène de givrage du compresseur du congélateur 50p ?
Le congélateur 50p est utilisé dans le traitement industriel du froid, mais si ses performances ne sont pas bonnes, il peut entraîner des travaux industriels, surtout s'il est défectueux, il est plus difficile à résoudre. Par conséquent, il est préférable de comprendre les différents défauts du congélateur 50p...
50p freezer compressor return air frosting is a very common phenomenon in the refrigeration system. Under normal conditions, system problems will not be formed immediately, and the fine frosting will not be treated normally. If the frosting phenomenon is serious, it needs to be solved in time. The root cause of this situation is that the refrigerant flowing through the evaporator does not fully absorb the heat required to expand itself to a predetermined pressure temperature value.
The temperature and pressure volume values that cause the 50p freezer to return to the air are relatively low. This problem may be caused by the evaporator not being able to absorb heat normally, or the cold volume generated by the evaporator cannot be taken away. The representation is that the return liquid temperature and pressure are normal or slightly lower, and the compressor is gradually condensed toward the evaporator from the gas return port. After a long time, all the ice is frozen from the compressor return port to the evaporator and the throttle valve to the evaporator section. , there is a low pressure. Since the amount of refrigerant is too small, the evaporation pressure of the evaporator is low, resulting in low evaporation temperature, which will gradually lead to condensation of the evaporator to form a heat insulation layer and transfer the expansion point to the compressor return air to cause the compressor to return to the air. If the amount of fluorine is normal or excessive, and if there is a situation such as excessive condensation heat exchange, the high pressure is low, then the refrigerant at the front end of the throttle valve under the same volume will show low pressure and high quality.
At the initial throttle opening, the quality of the refrigerant liquid flowing through the throttle valve will be more than normal, and the amount of heat that needs to be absorbed from the evaporator will be excessive. If the corresponding heat is not completely absorbed from the evaporator, the compressor will be returned. The tracheal temperature is low. At the same time, due to the low pressure at the front end of the throttle valve, the back pressure of the throttle valve will also be low. If the Dalian 50p chiller installation system is an expansion valve, (detecting the return pipe temperature and pressure, the pipe temperature is reduced, The pressure reduction opening increases) Compared with the normal state opening, it will not make too much adjustment, then the low pressure will be maintained until the compressor returns to the frost, which seems to be deficient in fluorine (low pressure and low pressure) and low return pipe temperature. Causes frosting.
In operation, users must also recognize the benefits of high-performance 50p freezer for work operation. LNEYA uses high-profile branded accessories to operate equipment more efficiently.

Recommandations connexes
-
Bonne nouvelle ! Wuxi Guanya LNEYA Refrigeration change de nom
2635According to the `` Notice on Publishing the Evaluation Results of Unicorn and Gazelle Enterprises in the 2019 South Jiangsu National Independent Innovation Demonstration Zone '' issued by Jiangsu Sunan National Independent Innovation Demonstratio...
Voir les détails -
Quelles sont les caractéristiques de la réfrigération des refroidisseurs industriels ?
1187If there is a high temperature difference between the inlet and outlet water, then a large external tank will be used to store cold water. In this case, the cooling water will not be directly from the cooler application. Deep into the outside of t...
Voir les détails -
Maintenance steps of slope heating and cooling cooling heating thermostat
1009The slope temperature rise and fall cooling heating thermostat is the center to clean dust, garbage, etc. To clean and change inspection, inspection can find problems, find the potential defects of the slope temperature rise and fall high and low...
Voir les détails -
Good-Quality Liquid High&Low Temperature Impact Environment Chamber
1475When customers choose a liquid high and low-temperature impact environmental chamber for sale, first of all, they need to have a clear understanding of its use and characteristics.Functions of liquid high and low-temperature impact environmental c...
Voir les détails