Summary – the cause of the failure of the 85 ° C ultra-low temperature refrigerator
-85 ° C ultra-low temperature refrigerator in industrial cold treatment, with the development of industry, the scope of use is also wider. However, in the process of use, it will inevitably lead to failure, so how much do you know about common faults?
-85 °C ultra-low temperature refrigerator pressure is low, when the actual gas consumption is greater than the output gas volume, it will cause deflation valve failure, intake valve failure, hydraulic cylinder failure, load solenoid valve failure, the above failure will lead to pressure switch failure. -85 °C ultra-low temperature refrigerator exhaust pressure is too high, intake valve failure; hydraulic cylinder failure; load solenoid valve failure; pressure setting is too high; pressure sensor failure; pressure gauge failure; pressure switch failure.
-85 ° C ultra-low temperature refrigerator exhaust temperature is higher, may be due to the coolant level in the refrigerator is too low; oil cooler is dirty; oil filter core is blocked; temperature control valve failure; oil cut solenoid valve is not powered or The coil is damaged; the diaphragm of the oil-disconnecting solenoid valve is broken or aged; the fan motor is faulty; the cooling fan is damaged; the exhaust duct is not smooth or the exhaust resistance is large; the ambient temperature is outside the specified range; the temperature sensor is faulty; the pressure gauge is faulty.
-85 °C ultra-low temperature refrigerator with high fuel consumption or compressed air with large oil content, too much cooling dose, the correct position should be observed during loading, the oil level should not be higher than half; the return pipe is blocked; the installation of the return pipe does not meet the requirements The exhaust pressure is too low during operation; the oil separation core is broken; the internal separator of the separation cylinder is damaged; there is oil leakage; the coolant is deteriorated or overdue.
-85 °C ultra-low temperature refrigerator with large current, low voltage; loose wiring; pressure exceeds rated pressure; oil separation core is blocked; contactor failure; host failure; main motor failure; failure to start, fuse is broken; temperature switch is broken; The main motor thermal relay operates; the fan motor thermal relay operates; the transformer is broken; there is no power input; the fault is not eliminated; the controller is faulty. Fan motor overload, fan deformation; fan motor failure; fan motor thermal relay failure; loose wiring; cooler blockage;
If the above fault occurs in the -85°C ultra-low temperature refrigerator, it needs to be solved in time to avoid these common faults affecting normal operation.

Recommandations connexes
-
L'effet du chauffage et du refroidissement Traducteur
942L'ensemble de la circulation de liquide du circulateur de chauffage et de refroidissement est fermé par le vase d'expansion. Le vase d'expansion et la circulation du liquide sont adiabatiques et ne participent pas à la circulation du liquide. Il s'agit simplement d'une connexion mécanique...
Voir les détails -
Cautions for Ultra-low Temperature Freezer
10271. Requirements of equipment environment: To keep the outside of cryogenic refrigerator clean and ventilated, it is necessary to keep the horizontal position of cryogenic refrigerator stable, and to ensure that there are no sundries around.2. Mana...
Voir les détails -
Lneya Semiconductor Refrigeration Heating Circulation Wind System Test Description
1194Le système de réfrigération et de chauffage à circulation d'air pour semi-conducteurs comporte de nombreux éléments d'essai. Dans quelle mesure les utilisateurs connaissent-ils les tests hors canal du système de réfrigération et de chauffage à circulation d'air des semi-conducteurs ? Le test hors canal...
Voir les détails -
Description de l'importance du fonctionnement de l'équipement du cycle à basse température
1086The use of low-temperature cycle equipment is inseparable from its standard operation. LNEYA low-temperature cycle equipment will be shipped with the corresponding instruction manual, and users can know ahead of time when using it. The low tempera...