Detailed Introduction of Air Cooled Chiller Equipment
LNEYA refrigeration has accumulated over 10 years of cooling supporting application experience. According to different application fields and service conditions, it has developed a variety of types of cooling chillers, including air cooled chillers and water cooled chillers, which can well meet the needs of equipment cooling. The heat dissipation device of air cooled chiller is a built-in fan, which mainly has three interrelated systems: refrigerant circulation system, water circulation system and electrical automatic control system.
1. Refrigerant circulation system: the liquid refrigerant in the evaporator absorbs the heat in the water and begins to evaporate. Then, a certain temperature difference is formed between the refrigerant and the water. After the liquid refrigerant is completely evaporated and becomes gaseous, it is inhaled and compressed by the compressor (pressure and temperature increase). The gaseous refrigerant absorbs heat through the condenser and condenses into liquid. After throttling through the expansion valve, the low-temperature and low-pressure refrigerant enters the evaporator to complete the refrigerant circulation process.
2. Water circulation system: the water pump is responsible for pumping water from the water tank to the equipment that needs to be cooled. After the heat is taken away by the chilled water, the temperature rises, and then returns to the chilled water tank.
3. Electrical automatic control system: including power supply part and automatic control part. The power supply part supplies power to the compressor, fan, water pump, etc. through the contactor. The automatic control part includes temperature controller, pressure protector, time delayer, relay, overload protector, etc. combined with each other to achieve the functions of automatic opening or suspension and other protection according to the temperature requirements.
Our air cooled chillers can be widely used in medical, biological, chemical, laser, metallurgy, equipment manufacturing, electroplating, plastic processing and other industries. Please consult us for details.
Recommandations connexes
-
Troubleshoot fan failures in the cooling system of the engine powertrain
989The fan is generally installed at the upper end of the cooling system of the engine powertrain, and some customers choose to install it on the side according to regulations. For screw chillers that use fans to dissipate heat, they are called air-c...
Voir les détails -
Lneya’s high and low temperature cooling circulator instructions
1102The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according...
Voir les détails -
Comment gérer l'alarme de défaillance de l'équipement du refroidisseur à recirculation ?
926Que faire en cas de panne et d'alarme pendant l'utilisation de l'équipement de refroidissement à recirculation ? Afin d'assurer la production, ces problèmes doivent être résolus rapidement. Nous devons d'abord comprendre les causes des pannes et des alarmes, et adopter dif...
Voir les détails -
Basic maintenance of high and low temperature refrigeration circulating pumps
1412Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protect...