Principle Analysis of Glycol Chiller
Glycol chiller is an industrial chiller
with glycol as refrigerant. The structure of glycol chiller is roughly the same
as that of ordinary industrial chiller, which is composed of compressor,
evaporator, condenser and electric control system. In order to ensure the
stable operation of glycol chiller, we suggest that you take explosion-proof
measures and buy explosion-proof glycol chiller as far as possible.
1、 Operation of compressor
In order to ensure that the pressure inside
the evaporator is low enough and that the refrigerant is at such a low
temperature, the compressor is used to extract the evaporated refrigerant and
compress the low temperature and low pressure into high temperature and high
pressure refrigerant gas.
2、 Use of condenser
High temperature and high pressure
refrigerant condenses into liquid in the condenser. The refrigerant in the
condenser releases heat in air or water lower than its temperature. Of course,
the temperature of air or water must be lower than that of refrigerant.
3、 How to throttle
After passing through the restrictor, the
refrigerant of the chiller drops from the condensation pressure to the
evaporation pressure, so the liquid from the condenser can be placed in the
liquid reservoir. At this time, the refrigerant is in the state of normal
temperature and high pressure, and then passes through the expansion valve to
reduce the boiling point, enters the evaporator, and the liquid absorbs heat
and evaporates.
4、 Endothermic evaporation
After passing through the restrictor, the
refrigerant liquid with low temperature and low pressure exchanges with the
evaporator, and the absorbed heat becomes saturated or superheated steam.
Recommandations connexes
-
Application of crystallization technology of ultra-low temperature chiller in petroleum industry
922This article mainly introduces the application of the freezing technology crystallization technology of industrial refrigerators in the oil industry and the principle of freezing crystallization. At present, the separation method using freeze crys...
Voir les détails -
Méthode d'entretien quotidien de la machine à cycle de refroidissement et de chauffage à huile caloporteuse
1140La machine à cycle de refroidissement et de chauffage à huile thermoconductrice est un ensemble de soutien de divers réacteurs dans l'industrie pharmaceutique et chimique. Le réacteur peut être utilisé pour le refroidissement ou le chauffage et présente un taux d'efficacité énergétique élevé. Il ne nécessite pas de...
Voir les détails -
What are the main uses of the reactor heating and cooling unit?
1023The reactor heating and cooling device is suitable for high-purity metal, rare substance purification, laboratory environment simulation, magnetron sputtering, vacuum coating and other industries. Large cryogenic pump units can provide a cooling e...
Voir les détails -
How to solve the problem of returning oil in ultra-low temperature freezer?
1506The ultra-low temperature freezer will fail after a long period of use, and the user needs special attention when oil return occurs. In the ultra-low temperature freezer, the oil return is not smooth, which will cause a large amount of lubricating...
Voir les détails