The Noise Analysis of Precision Chiller
Generally speaking, even the most sophisticated refrigerating equipment will also have some trouble when used for a long time. If the noises present in the precision chiller after prolonged use, I am sure that it appears some faults. So let’s go deeper to see where these noises are from.
The noise of compressor
The compressor is in the core position of the inner structure of the precision chiller. In general, compressors include screw and stroll, you can pick up one as what you need. Once the compressor has some noise, the first thing you should do is to check out if the expansive valve is open excessively; if so, you ought to adjust it. Next, you should see if the freezing medium is overmuch; if so, you had better remove the needless refrigerators.
The noise of water pump
It is attributable to the water quality mainly if the water pump has some noises. I suggest that water treatment should proceed according to the requirement of the chillers.
The accessories lack lubricant
The configuration of most of chillers is made of metal. Once the accessories are short of lubricant, the frictions can not be avoided, making some noises. Besides, you have to keep maintenance in daily life to reduce the rate of faults.
Oil starvation because of overload
You can find out whether the compressor is fuel elan when there are some noises. If it is, you can refuel it. To check if the compressor is overloaded will help you solve it in time.
Through the introduction of precision chillers, you must have a better understanding. If you are eager to further study, you can follow Guanya Refigeration Technology Co., Ltd.
Recommandations connexes
-
Maintenance principle of fluorinated liquid TCU temperature control system
959Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place; (2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m; (3) The lo...
Voir les détails -
What are the decarboxylation reaction conditions and process temperature control?
1210The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group ...
Voir les détails -
Start-up work for new energy thermal management
1010In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
Voir les détails -
2019 CPHl China | LNEYA W5P22 Site d'exposition&Merveilleux
1069Du 18 au 20 juin 2019, la 19e exposition mondiale des matières premières pharmaceutiques de Chine - CPhI China 2019 s'est tenue au Shanghai New International Expo Center. LNEYA a apporté une variété d'équipements au stand W5P22, qui a duré trois ...
Voir les détails