The battery pack test temperature simulation chiller is more and more widely used in enterprises, but the subsequent maintenance and maintenance are also more important. Here is a brief introduction to some maintenance and maintenance methods.
1. The temperature of the battery pack that does not need to be opened is not closed before the start-up to simulate the water inlet valve of the condenser on the chiller, resulting in water leakage. Part of the cooling return water flows away from the condenser of the non-starting unit, reducing the cooling water flow in the condenser of the operating unit, causing the condensation pressure to rise, the operating current of the main engine to increase, and the cooling capacity of the unit to decrease. Stopping the operation not only wastes electricity, but also reduces the cooling effect, and is easy to damage the equipment.
2. Before starting up, close the water inlet valve of the condenser of the unit that does not need to be operated to prevent water leakage. Open the water inlet and outlet valves on the condenser of the unit to be operated (generally the outlet valve is normally open, the water inlet valve is opened and closed according to needs. The condenser and the evaporator are the same) and turn on the corresponding cooling water pump to adjust the water inlet and outlet pressure of the condenser.
3. If the pointer of the pressure gauge of the water inlet and outlet of the condenser swings too much, it means that there is air in the equipment system, and the air needs to be exhausted to continue to the next step after the pressure gauge indicates normal.
4. It adopts an intelligent main control board, and the LED display is stable and durable, with multiple settings and fault display functions; it is equipped with a water outlet pressure gauge, which is convenient for observing pressure and flow.
Recommandations connexes
-
Méthode de fonctionnement d'un système de circulation à haute et basse température pour le revêtement sous vide
1280In many current chemical experiments, the vacuum coating high and low temperature circulation system can be used, making the high and low temperature refrigeration heating system supporting the vacuum coating system, and the operation is more effi...
Voir les détails -
Test de semi-conducteurs Unité de circulation de chauffage à deux canaux
815Le cycleur de chauffage à deux canaux dans les tests de semi-conducteurs fait référence à un dispositif utilisé pour tester les dispositifs à semi-conducteurs (tels que les semi-conducteurs de puissance), qui peut contrôler simultanément deux canaux de test indépendants pour effectuer le chauffage et le refroidissement....
Voir les détails -
L'essai du moteur du compresseur du refroidisseur provoque l'usure
1094La qualité de l'huile de refroidissement des moteurs peut être l'une des principales causes de l'usure du vilebrequin. Si l'huile moteur est utilisée dans le système de réfrigération du refroidisseur, l'huile moteur qui ne répond pas aux exigences et qui est de mauvaise qualité peut provoquer une usure du vilebrequin...
Voir les détails -
Precautions for changing the refrigerating oil in the cooling system of the car charger
824The cooling system of the car charger should pay attention to the condition of the refrigerating oil during the operation. After the compressor is started, carefully observe the changes in the oil temperature and oil pressure. If the oil changes c...
Voir les détails