Comment tester les composants du régulateur de température de la puce à l'aide d'un multimètre ?
The chip temperature control device is used in components such as chips, semiconductors, and integrated circuits. How do you use a multimeter for these common components?
Transformers, deflection coils, compensation inductors, etc. of electronic components, because the resistance values of the inductive components wound by the wires are very low, the short-circuit faults of them are difficult to measure; the open-circuit faults depend on testing the resistance of the two ends of the components. Should be greater than its normal value (need to know its resistance in advance or find a similar type of component after testing). Test the forward and reverse resistance should comply with the PN junction law, the multimeter value is low blocking (R × 10 or R × 100), when the diode is connected in parallel with the capacitor, due to the capacitor charging and discharging, the test needs to wait for a while, until the resistance is stable. After the diode and the inductor are connected in parallel, the resistance of the inductor is small, which is invalid in the road test.
The forward and reverse resistance between the e-b or b-c poles of the test triode electronic components still conforms to the test rule of the PN junction, and the difference between the forward and reverse resistance values between the measured e-c is smaller. The high power tube is measured with R×100 or R×1K. It should be noted that the transistor is more complicated in the road condition, and only when the PN junction is actually broken or broken, can it be seen that when the resistance of the parallel component between the two poles is too low, it is effective to disconnect the one pole detection.
The measured value of the resistance of the test electronic component must be less than or equal to the nominal value of the resistor (as seen from the appearance of the resistor or see the mark on the schematic). If it is greater than the nominal value, the resistor is damaged. If it is a potentiometer or a semi-adjustable resistor, one end of the multimeter can be connected to the potentiometer moving point, and the other end can be connected to any point. When the shaft handle is rotated, the resistance value should be changed, and the measured resistance value should also be less than or equal to the nominal resistance value.
If there is no short-circuiting component at the two ends of the capacitor (such as an inductor coil), the resistance of the two terminals should be greater than zero, and the capacitor with a large capacity should be charged and discharged. Otherwise, the capacitor has broken down or failed.
Components can be judged by using a multimeter to test whether it is good or bad, which can improve the inspection speed of components, and is also beneficial to the effective operation of the chip temperature control equipment in the test work.

(Note: Some of the original content is from related papers. If infringement, please contact us in time to delete, thank you.)
Recommandations connexes
-
Le système de refroidissement et de chauffage ajoute une solution de température pour l'industrie pharmaceutique et chimique
992LNEYA is a professional manufacturer of various temperature control instruments for more than ten years. It is involved in the pharmaceutical, chemical, scientific research, industrial, new energy, chip and other industries. The research and devel...
Voir les détails -
Why does a chiller need to be installed for cooling the water storage tank?
1016The main reasons for configuring a chiller for cooling the water storage tank are related to the following aspects: Temperature Control: In many industrial and commercial applications, such as air conditioning systems, chemical processes, ...
Voir les détails -
Heat transfer oil for cooling and heating temperature control systems in the chemical and pharmaceut
1124The cooling and heating temperature control system, also known as a high and low temperature circulator or dynamic temperature control system, is a temperature control equipment used in the pharmaceutical and chemical industry to provide cold and ...
Voir les détails -
How is a low temperature chiller suitable for the mold industry?
926Everyone knows that the use of low temperature chillers is relatively extensive, especially in the mold industry. When the low temperature chiller is used to cool the mold, the mold is generally cooled together with the injection molding machine. ...