Core Maintenance Points of Ten High and Low Temperature Test Chamber Manufacturers
According to many years’ production experience of high and low temperature test chamber in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and low temperature test chamber. As one of the top ten manufacturers of high and low temperature test chamber, Wuxi Guanya has sorted out the relevant maintenance points, and everyone pays attention to the analysis.
Enterprise users need to have a comprehensive understanding of the products of ten manufacturers of high and low temperature test chamber before choosing. Because of the lack of correct judgment and sufficient recognition, enterprises can not choose high-quality high and low temperature test chamber. Among them, compressors, controllers, electronic devices, boxes and hardware fittings are very important, so the role of each component is very important and nursing is very important.
Cleaning of waterway and humidifier
If the waterway of the high and low temperature test chamber is not smooth, the scaling of the humidifier will easily lead to the dry burning of the humidifier, which may damage the humidifier. Therefore, the high and low temperature test chamber must be cleaned regularly for the waterway and the humidifier.
Selection of Test Environment
Generally speaking, the box of high and low temperature test chamber is relatively high. Ten manufacturers of high and low temperature test chamber suggest that it should be placed in a benign temperature environment when using. For laboratories that do not meet this requirement, it is necessary to equip with appropriate air conditioners.
Clean evaporator regularly
Many small particles such as dust will condense on the evaporator under the forced air circulation of the test sample in the high and low temperature test chamber. It needs to be cleaned regularly in the high and low temperature test chamber, otherwise it will seriously affect the normal use of the equipment.
Clean condenser regularly
The common high and low temperature test chamber usually uses air-cooled cooling compressor, so it is necessary to repair the condenser fan regularly and remove the dirt and dust from the condenser so as to obtain good ventilation and heat transfer performance.
These high and low temperature test chamber ten manufacturers collated the relevant maintenance knowledge, you can pay attention to check the early formulation of maintenance plan.
Recommandations connexes
-
Refrigeration and heating temperature control system for multiple reactors
9711. There are some differences in the quality and configuration of the refrigeration and heating temperature control systems of multiple reactors from different manufacturers. Some equipment will have some noise during operation, and the noise is l...
Voir les détails -
What should I do if there is noise from industrial cooling and heating chillers?
1131The industrial cooling and heating temperature control equipment adopts a PID algorithm temperature control system to accurately adjust the temperature based on the detected temperature and the set temperature value, improving the drawbacks of tr...
Voir les détails -
Description de la fonction de la boîte d'essai de choc thermique humide alterné à haute et basse température
932Les consommateurs doivent prêter attention aux performances de l'enceinte d'essai à choc thermique humide alternant des températures élevées et basses. L'enceinte d'essai de LNEYA est plus proche des besoins de l'entreprise acheteuse. L'enceinte d'essai à chaleur et chocs humides alternés à haute et basse température...
Voir les détails -
What are the system components of various distillation devices?
8341. A complete set of short-path distillation equipment: including short-path evaporator, heating system, feeding system, cooling system, vacuum system, material collection unit, etc.; 2. A complete set of thin film distillation equipment: includin...
Voir les détails