LNEYA high and low temperature heating refrigerator maintenance instructions
High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high and low temperature heating refrigerator is used for more than 150 degrees for a long time, check the heat transfer oil every three to six months, and decide whether to replace it according to the actual situation. When replacing the circulating oil, do not let water or foreign matter fall into the fuel tank.
Due to the thermal expansion and contraction during transportation and work in the middle of the machine, the nut of the terminal may be loosened, resulting in excessive current causing oxidation of the copper of the terminal, causing the short circuit to burn out the heating tube and the contactor. Maintenance of the heating tube of the high and low temperature heating chiller requires attention. Remove the sealing plate after the machine, open the wiring cover of the heating tube, and use the corresponding size of the sleeve for the nut of each connection and the nut at the joint of the copper piece (including under the copper piece). The nuts are all tightened and reinforced. If the water/oil scale of the high and low temperature heating refrigerator is serious, the whole heating pipe should be removed, and the surface of the heating pipe and the inside of the heating pipe should be cleaned and maintained to prevent the heating pipe from being burnt out due to poor circulation of the system.
When using the equipment, be sure to open the cooling water inlet and outlet valves on the back of the machine, with or without cooling water. The water circulation high and low temperature heating refrigerator may need to avoid the high pressure power failure of the machine due to thermal expansion during the heating process, and the pressure of the cooling water remaining inside the cooler may be prevented from being ruptured due to heat exchange expansion. Causes oil and water to mix and the machine does not work properly.
When not in use, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water/heat transfer oil in the pipe, and store it in a dry place.

High and low temperature heating refrigerators need to be shut down for a period of time due to production. When restarting the machine, it is necessary to clean the filter and heating tube of the Y-type filter of the hot oil inlet to avoid the machine is not running for a long time, and the grease and impurities are deposited inside. The circulation is not smooth and the service life is shortened.
The maintenance of high and low temperature heating chillers is an important part of daily operation. Please keep in mind the high and low temperature heating chiller maintenance during the daily operation of the operator.
Recommandations connexes
-
Industrial grade heating and cooling system placement attention
1283Industrial-grade heating and cooling system Before the power is turned on, check whether the voltage specified on the nameplate is the same as the household voltage. The same can be used to arrange separate power lines and special sockets for the ...
Voir les détails -
Quelle est la gamme de régulation de la température des refroidisseurs industriels ?
1601Le refroidisseur industriel est un équipement de réfrigération courant dans l'industrie du froid industriel, qui se caractérise par ses différents types, ses modèles complets et sa large gamme d'applications.
Voir les détails -
Théorie de l'écoulement de la glace, qualité de l'eau glacée, débit et pression de la machine à eau glacée
879L'adoucissement de l'eau est également un problème important dans le processus d'utilisation des refroidisseurs. La valeur du pH de l'eau doit également être observée en permanence. La valeur optimale du pH doit être égale à 7. Une valeur de pH supérieure à 7 entraînera une terrible corrosion...
Voir les détails -
Equipment attention points of laboratory high and low temperature cycle equipment manufacturers
1089In the laboratory, a wide range of experimental instruments are widely used. When the experimental instruments are in operation, they are inseparable from the high-low temperature circulating device refrigeration heating equipment. What should be ...