Description détaillée de la réparation des vannes des machines intégrées à haute et basse température
The conventional high and low temperature integrated machine valve replaces the packing, and the main function of the packing is to prevent the working medium from leaking along the axial direction of the valve stem. In case of minor leakage, the packing gland can be tightened. If the leak cannot be eliminated, the packing should be replaced. When replacing, the valve stem must be screwed out to the end. Use the filler needle to pull out the old packing, then screw the prepared new packing in turn, and then tighten the gland.
In conventional high and low temperature integrated machine engineering, the valve core of a large diameter valve is sealed by a layer of babbitt or fluoroplastic. The back of the spool also has a layer of babbitt so that when the stem is rotated out of position, the working fluid can be sealed without leaking outward along the stem. After the valve is disassembled, first straighten the stem to deburr, then replace the valve’s babbitt alloy. At the same time, the valve seat should also be ground to make the valve core and the valve seat tight. For small cast steel or brass valve spools, the seal of this valve is obtained by a line of metal contact, hence the line seal. Because it is a wire seal, the valve seat and the valve core should be carefully ground to obtain a satisfactory sealing effect. After the valve is overhauled, the air tightness test shall be carried out in accordance with the relevant requirements.

The repair of the safety valve in the explosion-proof high-temperature integrated machine refrigeration system is also roughly the same as above, but since the babbitt alloy is soft, it is often difficult to return to the original position after the safety valve is operated once due to overpressure, so when the pressure is reduced to the closing pressure At the time, it is still not tight. In order to overcome this drawback, some products have changed the Babbitt alloy to a nickel-chromium-titanium (harder) alloy, or replaced with polytetrafluoroethylene.
The timely maintenance of conventional high and low temperature integrated machine valves can better help the operation of conventional high and low temperature integrated machines, so it is recommended to solve them in time.
Recommandations connexes
-
Le rôle du système de contrôle de la température TCU dans les réacteurs chimiques et pharmaceutiques
1311Le contrôle de la température de la marmite de réaction dans la recherche et le développement de médicaments et les expériences chimiques, ainsi que le contrôle de la température dans la production expérimentale à petite échelle et les processus de production industrielle, nécessitent une températ...
Voir les détails -
The difference between a large refrigeration and heating circulator and a test chamber
9221. For the high temperature test under special circumstances, the high and low temperature test chamber may not meet the requirements. Generally speaking, the high temperature upper limit of the high and low temperature test box is 200 ℃, and its ...
Voir les détails -
Performance Characteristics of 30 HP Water Cooled Chiller
1084The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for coo...
Voir les détails -
Description des performances d'un refroidisseur à recirculation pour bioréacteur
1041Le refroidisseur à recirculation convient à la réaction à haute et basse température de divers réacteurs en acier inoxydable, en émail, en alliage de titane, d'émulsifiants, de machines de moulage par injection, de cuves de mélange et de divers bioréacteurs. D'autres bioréacteurs en diffé...
Voir les détails