Comment choisir un refroidisseur et une machine de moulage par injection ?
A. First way:
The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.
The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force injection machine, and the temperature can be controlled at 10-15 degrees.
The 1HP water-cooled chiller can be equipped with 120 tons mould-locking force injection moulding machine, and the temperature can be controlled at 15-20 degrees.
(The matching of air-cooled chiller is 0.8 times that of water-cooled chiller, that is, the temperature of injection moulding machine of 1HP air-cooled chiller with 64 tons of clamping force is controlled at 5-10 degrees.)
B. The second way:
1HP water-cooled chiller can be equipped with injection moulding machine with a single injection volume of 10 QZ, and the temperature can be controlled at 5-10 degrees.
Injection Mold Quantity 1QZ=28.5g
The above formulas are the results summarized by the classics. In addition to the above formulas, the salesman should filter the actual situation and select the appropriate chiller.
C. Matching of chillers and cooling towers:
According to experience, 1HP chiller needs a cooling tower of 1.2 tons to take away the heat generated by the chiller.
We are a top chiller manufacturer. Welcome to buy our products.
Recommandations connexes
-
Refroidisseur à basse température pour le processus de fabrication de matériaux chimiques
9031. Les réactions sensibles à la température contrôlent de nombreuses réactions chimiques très sensibles à la température, notamment dans la synthèse de matériaux polymères, de produits pharmaceutiques intermédiaires et d'autres produits chimiques fins. Les réactions à basse temp...
Voir les détails -
The Refrigeration Principle of the Glycol Refrigeration System
1155Sometimes the refrigerant carrier needs to reach the temperature below 0 C. If the ice is carrying the cook, it will freeze, so adding some anti-freezing liquid can avoid freezing, and glycol can prevent freezing. glycol chillers ,
Voir les détails -
What are the conditions for the decarboxylation reaction? How to control the temperature of heating?
1211The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group i...
Voir les détails -
Unité de refroidissement à basse température dans la production de matériaux auxiliaires pour catalyseurs PGA
804Les refroidisseurs à basse température jouent un rôle important dans le processus de réaction de production de l'acide polyglycolique (PGA) et de ses catalyseurs et additifs. Les processus de synthèse et de post-traitement de l'acide polyglycolique impliquent souvent des réactions exothermiques, ...
Voir les détails