Instructions de chargement du réfrigérant pour les congélateurs à grande différence de température
Dans le cadre du développement de l'industrie moderne, les congélateurs à grande différence de température jouent également un rôle important dans le traitement du froid. Dans l'ensemble du processus de réfrigération du congélateur à grande différence de température, la charge du réfrigérant est également plus importante. Alors, comment...
For large-temperature-difference freezer refrigeration systems without high-pressure reservoirs and low-pressure vapor-liquid separators, the control of refrigerant charge is particularly important. Because the refrigeration system is a condenser and also acts as a high-pressure reservoir, the refrigerant is stored in the condenser, and the condenser is cooled. The heat dissipation area is reduced and the condensing pressure is increased, resulting in a decrease in cooling capacity.
For the control of the refrigerant charge of such a large temperature difference freezer, during the charging process, the temperature of the condenser casing should be touched, the upper outlet of the condenser outlet is heated, and the outlet below the outlet is cool (heating) It is indicated that there is a high-temperature exhaust gas of the compressor condensing inside, and the cooling is cold, indicating that the water-cooled large temperature difference refrigerator is a liquid space). Secondly, look at the suction pressure, which corresponds to the temperature of the refrigerant water in the evaporator (that is, corresponds to the evaporation temperature). Then, depending on the return temperature of the compressor of the large temperature difference refrigerator, the return pipe of the high temperature unit should be cooled and dew, but it can be dew condensation to the compressor return valve. The return pipe of the low temperature unit should be frosted, but the frost is compressed. The machine return valve is fine. If condensation or frost builds up on the compressor casing, liquid refrigerant will enter the crankcase, causing the compressor to run oil and liquid. For hermetic compressors, the motor terminals are also shorted. Although most of the closed unit terminals are sealed with a sealant, the possibility of a short circuit still exists due to the uncertainty of the sealing effect.
The above is the refrigerant charging method of Wuxi Guanya LNEYA finishing, hope to help everyone to run a large temperature difference freezer.

Recommandations connexes
-
How to replace the four-way valve of the chilled water machine?
1108The four-way valve of the chilled water machine needs to be replaced in time after a long period of use, so how to replace it? You can look at the suggestions. When replacing the chilled water machine, you need to remove the connecting pipe conne...
Voir les détails -
Comment juger de l'état de fonctionnement du système de contrôle de la température constante des produits chimiques et pharmaceutiques ?
952De nos jours, de nombreuses industries pharmaceutiques et chimiques utilisent le système de contrôle de la température constante de LNEYA. Comment juger de son état de fonctionnement pendant l'opération ? Il ne doit pas y avoir de bruit dans le cylindre du système de contrôle thermostatique des produits chimiques et pharmaceutiques...
Voir les détails -
What are the effects of oil level and oil difference in low temperature chillers?
1243LNEYA tells you that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil storage and special oil cooler. Oil level It refers to the level of the lubricant in the oil storage container. Th...
Voir les détails -
Temperature conditions of new energy vehicle batteries
891When automobile manufacturers continue to improve battery life to overcome the driver's mileage anxiety, the energy density of the large batteries installed is also gradually increasing, which means that the temperature monitoring function of the...
Voir les détails