Motor test bench environmental cabin option for new energy vehicles
Passenger car motor and commercial vehicle motor test bench can complete the stall torque and locked rotor current test, temperature rise test, continuous electric working characteristic test, motor maximum speed test, motor over speed test and feed operation characteristic test. At the same time, the test bench can feed the electricity generated during the test to the company’s power grid through the frequency conversion system.
Motor labs and performance dynamometers must contain functions that control the stimulating elements of the application, the most difficult of which is usually temperature cycling. Many systems are designed to be propelled into the environmental chamber and, if necessary, shield any sensitive power tool test components from extreme temperatures or humidity.
The measurement and control system consists of a host computer monitoring system, a data acquisition system, a sensor measurement system, a frequency converter control system, a test bench auxiliary equipment control system, a safety monitoring system, and an early failure warning system. The measurement and control system uses a real-time bus as the main communication network and a CAN bus that communicates with the device under test. The upper computer monitoring system communicates with the data acquisition system and the inverter control system through real-time bus, dynamically controls the motor in real time, collects the data of each sensor at high speed, and analyzes and processes the data. The lower computer controller communicates with each auxiliary test system, and controls the auxiliary test system, and simultaneously collects the sensor data of each safety monitoring, such as: motor temperature, bearing temperature, coolant temperature, cooling pressure, etc.; The DI/DO interface controls, for example, the system issues an emergency stop command, and the lower controller immediately outputs the corresponding DO signal to cut off the power of the corresponding system to ensure system safety.
LNEYA new energy battery motor test temperature control system KRY equipment is widely used in the industry, one can connect multiple test equipment at the same time, achieve precise temperature control, and do not interfere with the temperature control process.

(Some of the content comes from the Internet. If there is any infringement, you can contact and modify it, thank you!)
Recommandations connexes
-
Fonctionnement et entretien du système de refroidissement pour les essais à haute et basse température en alternance
1107La méthode de fonctionnement du système de refroidissement du refroidisseur pour les essais à haute et basse température en alternance : 1. Confirmer que l'état des vannes concernées dans l'unité répond aux exigences de démarrage. 2. Alimenter le dispositif de contrôle électrique de l'unité...
Voir les détails -
Analyse du prix des congélateurs ultra-bas
1218Quelles sont les caractéristiques et les fonctions du congélateur ultra-bas:1. le congélateur ultra-bas peut empêcher la précision de l'équipement de la machine d'être influencée par le changement de la température de l'huile dans le processus de fonctionnement. 2. Le congélateur ultra-bas peut empêcher...
Voir les détails -
Instructions relatives aux fuites internes des réfrigérateurs antidéflagrants à ultra-basse température
12961. Sound leak detection method: First, the refrigeration pipeline of the explosion-proof ultra-low temperature refrigerator is filled with nitrogen. Then use a stethoscope to check the interior. When you hear a leak in a certain area, mark it. Car...
Voir les détails -
LNEYA’s 300,000 kcal air-cooled unit on air tightness
1129When the user runs the 300,000 kcal air-cooling unit, it needs to check the air tightness, because the airtightness may cause the air-cooling unit to consume too much energy. In order to prevent the temperature from falling for a long time during ...
Voir les détails