Mode d'emploi du circulateur de chauffage et de refroidissement
Heating cooling circulator is a process that refrigerant transfers heat from low temperature state to high temperature state, so that its cooling can reach the state of low temperature environment, thus maintaining the low temperature state and realizing the refrigeration process. In the heating process of heating cooling circulator, heat is the process of heating with heat conducting oil to provide heat source, because the low temperature state is impossible to provide heat as the high temperature state.
Refrigeration cycle includes compression refrigeration cycle, absorption refrigeration cycle, adsorption refrigeration cycle, steam jet refrigeration cycle and semiconductor refrigeration cycle, etc. Heating cooling circulator of Wuxi Guanya mainly adopts compressor refrigeration cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of reverse Carnot cycle, so it can be regarded as reverse Brayton cycle. In engineering application, compressor can be piston type or impeller type. After entering the compressor, the air from the heating and refrigeration cycle equipment is adiabatically compressed, and the temperature rises above the ambient temperature. Then it enters the cooler and transfers the heat to the cooling water at a constant pressure, the temperature is equal to the ambient temperature. Then the expander is introduced to adiabatic expansion, and the temperature is further reduced to below the temperature of the heating and refrigeration cycle equipment. Then it enters the heating and refrigeration cycle equipment, which absorbs heat at constant pressure (the heat absorbed is called refrigeration capacity), and completes the cycle.
After the refrigerant is vaporized and absorbs heat from the chauffage refroidissement circulateur at constant pressure (at this time the working medium is usually dry saturated steam or near dry saturated steam), it enters the compressor to compress in adiabatic state, the temperature exceeds the ambient temperature, and then enters the condenser to heat the ambient medium at equal pressure. In the condenser, the superheated refrigerant vapor is first isobarically cooled to the saturated temperature corresponding to the current pressure, then continues isobaric (which is also isothermal) condensation to the saturated liquid state. It enters the throttle valve, adiabatic throttle at the throttle valve to reduce temperature and pressure to the wet saturated vapor state corresponding to the starting pressure of the cycle, and then enters the heating and refrigeration cycle equipment to gasify and absorb heat to complete the cycle.
Recommandations connexes
-
Operation and Maintenance of Small Water Chiller Units
9552. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advanta...
Voir les détails -
La sécurité de l'huile caloporteuse dans les refroidisseurs à eau
1039Afin d'obtenir une meilleure efficacité de fonctionnement, les refroidisseurs à eau doivent choisir une huile de transfert de chaleur de marque, mais vous devez faire attention à un placement sûr, un peu de négligence entraînera des effets néfastes. Bien que l'huile caloporteuse de t...
Voir les détails -
Effet de l'instrument d'évaporation pour l'expérience à basse température sur le système de réfrigération
1185According to different models, the choice of evaporators for low-temperature experiment special instruments is also different, such as box-type low temperature experiment special instruments, using water tank coil evaporator; open low temperature ...
Voir les détails -
Quelles sont les précautions à prendre pour l'installation d'un refroidisseur au glycol ?
1046En été, l'utilisation des refroidisseurs de glycol est relativement fréquente. Par conséquent, lors de l'installation des refroidisseurs de glycol, il est nécessaire de les installer sur un sol lisse et propre. Pourquoi choisir un sol lisse lors de l'installation ? Les utilisateurs qui ont connu les refroidisseurs de glycol...
Voir les détails