Organic waste gas recovery unit refrigeration oil requirements description
The organic waste gas recovery device is slightly different for different gases. The LNEYA organic waste gas recovery device and the vocs gas condensation recovery device are operated by the principles of condensation and adsorption. The refrigeration oil is also important, then the refrigeration oil has What is the requirement?
The cloud point of the frozen oil of the organic waste gas recovery device refers to the temperature at which the paraffin is precipitated in the frozen oil and the lubricating oil becomes turbid when the temperature is lowered to a certain value. The cloud point of the refrigeration oil used in the device should be lower than the evaporation temperature of the refrigerant, otherwise it will cause the throttle valve to block or affect the heat transfer performance.
The temperature at which the frozen oil is cooled under experimental conditions to stop flowing is referred to as the freezing point. The freezing point of the frozen oil used in the organic waste gas recovery device should be as low as possible (such as R22 compressor, the refrigeration oil should be below -55 °C), otherwise it will affect the flow of the refrigerant and increase the flow resistance, resulting in poor heat transfer. as a result of.

An important parameter in the characteristics of the oil viscosity of the refrigerating oil. Different refrigerants should be used to select different refrigerating oils. If the viscosity of the frozen oil is too large, the mechanical friction power, friction heat and starting torque will increase. On the other hand, if the viscosity is too small, the desired oil film cannot be formed between the moving parts, so that the desired lubrication and cooling effect cannot be achieved.
The flash point of a frozen oil is the temperature at which the lubricating oil is heated to the point where it is ignited when it comes into contact with the flame. The flash point of the frozen oil used in the organic waste gas recovery device must be 15 to 30 ° C higher than the exhaust gas temperature to avoid burning and coking of the lubricating oil. Organic waste gas recovery devices such as chemical stability and oxidation resistance, moisture and mechanical impurities, and insulation properties.
As far as the current environmental protection trend is concerned, if the company has organic waste gas, it is recommended to buy an organic waste gas recovery device for gas treatment as soon as possible to avoid troubles.
Recommandations connexes
-
Maintenance of Glycol Cooling Heating Control System
1157Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control System are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Re...
Voir les détails -
Brève présentation du thermostat de chauffage et de refroidissement à courbe antidéflagrante
995Le thermostat de chauffage et de refroidissement à courbe antidéflagrante de la série SUNDI adopte la technologie de réfrigération par compresseur et de chauffage par liaison, un système de tuyauterie intégré et un échangeur de chaleur à plaques. Il convient aux équipements reliant les réacteurs pour la réf...
Voir les détails -
Il existe généralement trois façons de contrôler la température des réacteurs de laboratoire
9481. Manual control: Manually operate the knob on the front of the reactor controller.2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.3. Controlled by thermostat: Silicone oil...
Voir les détails -
Étapes de débogage d'un refroidisseur d'eau industriel dans l'industrie chimique
1088Après avoir terminé l'installation des refroidisseurs d'eau industriels dans les entreprises chimiques, il est nécessaire de procéder à un certain débogage au début de la phase d'exploitation. Ce n'est qu'en procédant à un débogage minutieux que nous pouvons...
Voir les détails