Summary of Maintenance Items of Glycol Chiller
During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out necessary daily maintenance.

Inspection of refrigeration system of glycol chiller: generally, various problems will inevitably occur after long-term use of glycol chiller. Once there is a fault, we should carefully check the service condition of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system, and judge whether their functions are normal. We usually check them through sound and appearance. If there are problems, we suggest to replace them in time.
Refrigerant inspection of glycol chiller: regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of glycol chiller is also different. When the low-temperature chiller works normally, the high-pressure display is 11-17kg and the low-pressure display is 3-5kg.
Inspection of cooling water system of glycol chiller: check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.
System cleaning of glycol chiller: the glycol chiller shall be cleaned once a year after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good refrigeration effect.
Voltage and current inspection of glycol chiller: regularly check whether the voltage and electric flow of glycol chiller are stable and whether the compressor operates normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
Of course, there are many other details that need your attention.
Recommandations connexes
-
Découvrez les performances des accessoires de congélation industrielle LNEYA
764Régulateur de température Le régulateur de température est utilisé pour le contrôle ou la protection de l'appareil. Lorsque la température atteint la valeur réglée, l'interrupteur coupe (ou rallume) automatiquement le circuit. Dans nos produits, le contrôle de la température est souvent...
Voir les détails -
Instructions d'entretien du condenseur du circulateur de réfrigération à très basse température
1423La maintenance est une tâche importante pour les utilisateurs de circulateurs de réfrigération à très basse température. Wuxi Guanya LNEYA rappelle que l'entretien du condenseur est une tâche relativement importante dans son travail de maintenance. Quels sont donc les points auxquels il faut prêter attention ?
Voir les détails -
Les fabricants d'équipements à haute et basse température analysent les connaissances en matière de détendeurs.
1119Le détendeur est un accessoire important de la machine intégrée à haute et basse température. Le fabricant vous dit qu'il existe plusieurs types de détendeurs, et que les différents détendeurs présentent des différences. Le détendeur haute et ...
Voir les détails -
Knowledge Sharing Of Chiller Selection And Maintenance
1166Chillers can be used in a lot of industry, but who is the better low temperature chiller manufacturer in top chiller manufacturers?Let me tell you. The choice of own model and the maintenance are also very important. Next, see with me. 1. Range of...
Voir les détails