How to maintain the lubrication system of water-cooled chillers
Medium-sized water cooled chiller,
refrigeration temperature range from -80 ℃~ -30℃, safe,
reliable, rapid cooling for the liquid, widely used in petrochemical, medical,
pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.
When the water cooled chiller is below 80℃ ~ 30℃ below zero
in the running system, people pay more attention to refrigerator, frozen water
cycle system and electric control system, so the lubrication system is often
overlooked. However, this system is also very important to the water cooled
chiller. The maintenance of the water cooled chiller is indispensable, now we
are going to tell you something about it.
1. Observe the normal oil surface, oil
temperature and oil pressure in the daily inspection.
2. Regularly check the oil quality
according to the oil change index stipulated in the frozen lubricating oil, and
replace or supplement the filtered new oil.
3. Pay attention to check and adjust the
end face clearance of the oil pump in the middle and overhaul, and replace the
pump when necessary. The end face clearance of the pump varies from 0.03 to
0.08mm. Please refer to the assembly technical requirements and factory
regulations of the pump for concrete value.
4. Regularly replace or clean the filter
core, pipeline, and crankcase.
The maintenance of the lubrication system
of the water cooled chiller requires techniques, which mainly involves the
performance of the compressor’s main engine. It is recommended to be operated
by professionals to avoid unnecessary losses.
If you are purchasing our LNEYA
water-cooled chiller, you can contact our after-sales team. If you have
purchase needs or questions in this regard, you can also contact our team
sales@lneya.com, we will reply to you as soon as possible.
Recommandations connexes
-
Organic waste gas treatment device noise description
1405With the increasingly stringent environmental requirements, various manufacturers have paid more and more attention to their own organic waste gas treatment. LNEYA organic waste gas treatment equipment specializes in the treatment of various organ...
Voir les détails -
Description de la gamme d'applications du système d'essai de température des semi-conducteurs
1493Le système d'essai de température des semi-conducteurs est le nouveau dispositif de LNEYA pour l'essai des puces à semi-conducteur. Quelle est la plage d'application du système d'essai de température des semi-conducteurs ? Les utilisateurs doivent comprendre la plage d'application spécifique pour sélectionner le système approprié...
Voir les détails -
Analyse des caractéristiques des refroidisseurs industriels refroidis par air
936Les refroidisseurs industriels à condensation par air sont généralement des machines intégrales, c'est-à-dire que l'évaporateur, le compresseur et le condenseur sont fabriqués ensemble. Pour un refroidisseur industriel à condensation par air de puissance légèrement élevée, la dissipation thermique du ventilateur de refroidissement du condenseur doit être...
Voir les détails -
Le rôle des réchauffeurs à recirculation dans les instruments de réaction chimique et biologique
820Temperature Control: The recirculating heater provides a precise and stable temperature control environment, which is a crucial factor in chemical and biological reactions. Different chemical reactions and biological processes have spec...
Voir les détails