What are the common debugging problems in low temperature refrigeration baths?
When the low-temperature cooling bath is in debugging, if the local cooling effect is not good, the system may be blocked by foreign matter or the system design is unreasonable and cannot be adjusted normally. At this time, LNEYA removes foreign matter and thoroughly cleans it to adjust the slope of the pipeline.
When debugging, it is found that the vibration and noise of the pump are large when it is running. It may be that the axial and radial deviation of the coupling is large. It may be that the pump flange is too large and the anchor bolts are unevenly stressed. It is the natural vibration frequency of the pump and the pipeline that cause resonance. At this time, the axial and radial deviation of the coupling are adjusted quickly. Adjust the natural vibration frequency between the pump and the pipe, install the relevant soft joint parts, replace the flange and make the anchor bolts evenly.
During commissioning, it was found that the cooling capacity could not reach the required fixed value. It may be that the cooling tower water temperature did not reach the specified cooling parameter, or the pump output was insufficient, or the condenser isolation gasket was misplaced and could not be cooled, or the pipeline in the condenser was blocked. Repair the cooling tower to meet the water temperature and water requirements, remove foreign matter in the pipeline, and check if the condenser isolation gasket is misaligned.

If the exhaust pressure is too high, it is necessary to pay attention to whether the cooling water is insufficient, whether the condensation in the condenser heat transfer tube is serious, whether the cooling water temperature is too high, whether there is too much air in the system, check the cause, repair the cooling tower, and heat transfer of the condenser. The tube is cleaned to remove air from the system.
If severe frost formation is found, check if the return air filter is clogged, if the exhaust air volume is loose after the fan belt is loose, and if the return air valve is too small, it is recommended to clean the return air filter and adjust the fan belt. Adjust the size of the return air valve.
Common faults encountered in the commissioning of these low-temperature refrigeration baths, we try to check them before debugging, try to avoid these faults.
Recommandations connexes
-
Wuxi Guanya : se concentrer sur la recherche et le développement d'équipements de réfrigération et de chauffage pour contribuer au développement des nouvelles énergies
1386Le 17 octobre 2018, l'API de trois jours s'est tenue au Centre international d'exposition de Nanjing. L'exposition était bondée de monde. Wuxi Guanya était un visiteur fréquent de l'API. Wuxi Guanya Constant Temperature Refrigeration Technology Co, Ltd. (ici...
Voir les détails -
Automotive Coolant (ELC) Test Benefits and Introduction to coolant conditioner system
1088The cooling system is one of the main components of the engine. Its main function is to protect the engine from corrosion, pitting, corrosion and overheating. It is compatible with different engine materials and lubricates the engine cooling pump....
Voir les détails -
Explosion-proof cryogenic refrigeration unit icing, do you know what is going on?
1305When using an explosion-proof cryogenic refrigeration unit, many users do not know how to solve the problem of icing and frosting. In fact, the professional can tell you with certainty, no. The two causes are different, so the processing method is...
Voir les détails -
New energy vehicle high and low temperature test system
912With the popularity of new energy vehicles, high and low temperature tests have become a factor that car owners need to consider when purchasing new energy vehicles. Since the environment in which new energy vehicles are used is harsher, it is als...
Voir les détails