Recherche dans l'ensemble de la station

SUNDI series Chiller and Heater Combo Units

SUNDI series Chiller and Heater Combo Units

CANDIDATURES

Dynamic constant temperature control of cold and hot sources of high-pressure reactors;

Dynamic constant temperature control of cold and hot sources of double-layer glass reactors;

Dynamic constant temperature control of cold and hot sources of double-layer reactors;

Constant temperature control of cold and hot sources of microchannel reactors;

Small constant temperature control systems, distillation system temperature control;

Low-temperature and high-temperature aging tests of materials;

Constant temperature control of combined chemical cold and hot sources;

Cooling and heating of semiconductor equipment;

Constant temperature control of refrigeration and heating of vacuum chambers.

 

 

 

Modèle SUNDI-320                SUNDI-320W
Temp range -30℃~180℃
Medium temp accuracy ±0.5℃

Material temp accuracy

±1℃

Puissance de chauffage 2kW
Refroidissement
capacité
180℃ 1,5 kW
50℃ 1,5 kW
0℃ 1,5 kW
-5℃ 0.7kW
-15℃ 0,4 kW
Flow、pressure max10L/min
0,8bar
Réfrigérant R-404A/R507C
Taille de la connexion ZG1/2
Dimension en cm 35*56*75
Poids kg 55 kg
Puissance AC 220V 50HZ 3.2kW(max)

 

 

Modèle SUNDI-135
SUNDI-135W
SUNDI-155
SUNDI-155W
SUNDI-175
SUNDI-175W
SUNDI-1A10
SUNDI-1A10W
SUNDI-1A15
SUNDI-1A15W
Temp range  -10℃~+150℃
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control Modèle de contrôle de la température du processus et de la température de l'enveloppe
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 3.5 5.5 7.5 10 15
Refroidissement
capacité
150℃ 3.5 5.5 7.5 10 15
20℃ 3.5 5.5 7.5 10 15
-5℃ 2.1 3.3 4.2 6 9
Flow、pressure max
L/min bar
35 35 50 50 75
1 1 1.2 1.2 1.2
Compresseur Highly / Panasonic / Emerson copeland / scroll compressor
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R507C
Taille de la connexion ZG3/4 ZG3/4 ZG1 ZG1 ZG1
Eau de refroidissement
@20℃
1300L/H
1,5bar~4bar
ZG1/2
1800L/H
1,5bar~4bar
ZG3/4
1800L/H
1,5bar~4bar
ZG3/4
2400L/H
1,5bar~4bar
ZG3/4
3600L/H
1,5bar~4bar
ZG1
Dimension en cm 45*70*160 45*70*160 55*70*175 55*70*175 70*85*185
Poids kg 165 185 235 280 300
Puissance 380V 50HZ 6.7kW 9,5 kW 12kW 15.5kW 23kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
OptionalPower 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase

 

Modèle SUNDI-235
SUNDI-235W
SUNDI-255
SUNDI-255W
SUNDI-275
SUNDI-275W
SUNDI-2A10
SUNDI-2A10W
SUNDI-2A15
SUNDI-2A15W
SUNDI-2A25
SUNDI-2A25W
SUNDI-2A38W SUNDI-2A60W SUNDI-2A95W SUNDI-2A130W SUNDI-2A200W
Temp range -25℃~+200℃(can be -25℃~+300℃)
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control Modèle de contrôle de la température du processus et de la température de l'enveloppe
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Refroidissement
capacité
200℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
50℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
-5℃ 3 4.5 6.3 8 11 19 30 46 70 80 125
-15℃ 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Flow、pressure  max
L/min bar
35 35 50 60 110 150 200 250 400 400 600
1.2 1.2 1.2 1.2 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Compresseur Tecumseh Emerson copeland / Carlyle
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R507C
Taille de la connexion ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 DN40 DN50 DN65 DN65 DN80
Eau de refroidissement
@20℃
1500L/H
1,5bar~4bar
ZG1/2
1800L/H
1,5bar~4bar
ZG3/4
3000L/H
1,5bar~4bar
ZG3/4
4200L/H
1,5bar~4bar
ZG3/4
5400L/H
1,5bar~4bar
DN32
10m³/H
1,5bar~4bar
DN40
10m³/H
1,5bar~4bar
DN40
14m³/H
1,5bar~4bar
DN50
19m³/H
1,5bar~4bar
DN65
24m³/H
1,5bar~4bar
DN65
36m³/H
1,5bar~4bar
DN80
Dimension en cm 45*70*160 45*70*160 55*70*175 65*85*185 70*85*185 80*120*185 150*100*185 200*145*205 200*145*205 250*145*225 300*160*225
Poids kg 165 185 230 280 300 550 750 1000 1250 1580 2150
Puissance 380V 50HZ 6.7kW 9,5 kW 15kW 16kW 27kW 48kW 55kW 81kW 126kW 175kW 260kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
OptionalPower 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase
En option SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW

 

Modèle SUNDI-525
SUNDI-525W
SUNDI-535
SUNDI-535W
SUNDI-555
SUNDI-555W
SUNDI-575
SUNDI-575W
SUNDI-5A10
SUNDI-5A10W
SUNDI-5A15
SUNDI-5A15W
SUNDI-4A25
SUNDI-4A25W
SUNDI-4A38W SUNDI-4A60W SUNDI-4A95W SUNDI-4A130W SUNDI-4A200W
Temp range   -45℃~+250℃
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control Modèle de contrôle de la température du processus et de la température de l'enveloppe
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Capacité de refroidissement 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
0℃ 1.8 3 5 7 10 15 25 38 60 95 130 200
-20℃ 0.85 1.5 2.3 3.6 5 7.6 11 20 29 42 54 98
-35℃ 0.25 0.45 0.9 1.5 2 3.8 4.7 9 12 18 24 43
Flow、pressure max       L/min bar 20 35 35 50 60 110 150 200 250 400 400 600
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Pompe de circulation Pompe à entraînement magnétique
Compresseur Tecumseh/Emerson copeland/Carlyle
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R507C
Taille de la connexion ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1 DN32 DN50 DN50 DN65 DN65 DN65
Eau de refroidissement
@20℃
900L/H
1,5bar~4bar
ZG1/2
1400L/H
1,5bar~4bar
ZG1/2
1800L/H
1,5bar~4bar
ZG3/4
2400L/H
1,5bar~4bar
ZG3/4
3600L/H
1,5bar~4bar
ZG1
4800L/H
1,5bar~4bar
ZG1
9m³/H
1,5bar~4bar
DN40
10m³/H
1,5bar~4bar
DN50
15m³/H
1,5bar~4bar
DN50
20m³/H
1,5bar~4bar
DN65
32m³/H
1,5bar~4bar
DN80
46m³/H
1,5bar~4bar
DN100
Dimension en cm 45*70*160 45*70*160 55*70*175 55*70*175 65*85*185 70*85*185 80*120*185 150*100*185 200*145*205 200*145*205 250*145*225 300*160*225
Poids kg 160 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50hz AC220V 4kW 7kW 9kW 13kW 16kW 26kW 42kW 57kW 82kW 136kW 183kW 309kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
OptionalPower 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase
En option SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW

 

Modèle SUNDI-625
SUNDI-625W
SUNDI-635
SUNDI-635W
SUNDI-655
SUNDI-655W
SUNDI-675
SUNDI-675W
SUNDI-6A10
SUNDI-6A10W
SUNDI-6A15W SUNDI-6A25W SUNDI-6A38W SUNDI-6A60W
Temp range  -60℃~+250℃
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control Modèle de contrôle de la température du processus et de la température de l'enveloppe
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 2.5 3.5 5.5 7.5 10 15 25 38 60
Capacité de refroidissement 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
-40℃ 0.95 1.45 2.3 3.1 4.8 7.8 18 23 31
-55℃ 0.25 0.5 0.75 0.9 1.5 2.8 6 8 11
Flow、pressuremax  L/min bar 20 35 35 50 60 110 150 200 250
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5
Pompe de circulation Pompe à entraînement magnétique
Compresseur Tecumseh/Emerson copeland/Carlyle
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R23
Taille de la connexion ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 DN40 DN50
Eau de refroidissement
@20℃
1100L/H
1,5bar~4bar
ZG1/2
2000L/H
1,5bar~4bar
ZG3/4
2300L/H
1,5bar~4bar
ZG3/4
2600L/H
1,5bar~4bar
ZG3/4
3300L/H
1,5bar~4bar
ZG1
4000L/H
1,5bar~4bar
ZG1 1/4
8,5m³/H
1,5bar~4bar
DN40
14m³/H
1,5bar~4bar
DN50
20m³/H
1,5bar~4bar
DN65
Dimension en cm 55*70*175 55*70*175 55*70*175 65*85*185 65*85*185 80*120*185 150*100*185 200*145*205 200*145*205
Poids kg 205 225 300 340 380 380 980 1350 1580
Puissance 380V 50HZ 5kW 10kW 12kW 18kW 22kW 28kW 56kW 73kW 110kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
OptionalPower 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase
En option SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW

 

Modèle SUNDI-825W SUNDI-835W SUNDI-855W SUNDI-875W SUNDI-8A10W SUNDI-8A15W SUNDI-8A25W SUNDI-8A38W SUNDI-8A60W SUNDI-8A80W
Temp range  -80℃~+250℃
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control The material temperature control and equipment outlet temperature control modes can be freely selected
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 3 3.5 5.5 7.5 10 15 25 38 60 80
Capacité de refroidissement 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
-60℃ 1 1.4 1.6 3 3.5 5.8 10 16 23 32
-75℃ 0.3 0.42 0.7 1.3 1.5 2.4 5 8 11 16
Flow、pressuremax
L/min bar
20 35 35 50 60 110 150 250 400 400
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5
Pompe de circulation Pompe à entraînement magnétique
Compresseur Emerson copeland/Carlyle
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R508B
Taille de la connexion ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 DN40 DN65 DN65
Eau de refroidissement
@20℃
1800L/H
1,5bar~4bar
ZG3/4
2000L/H
1,5bar~4bar
ZG3/4
2800L/H
1,5bar~4bar
ZG3/4
3500L/H
1,5bar~4bar
ZG1
4200L/H
1,5bar~4bar
ZG1
5600L/H
1,5bar~4bar
DN32
10m³/H
1,5bar~4bar
DN40
18m³/H
1,5bar~4bar
DN65
28m³/H
1,5bar~4bar
DN80
30m³/H
1,5bar~4bar
DN80
Dimension en cm 55*70*175 55*70*175 65*85*185 70*85*185 70*85*185 80*120*185 150*100*185 200*145*205 245*170*225 300*160*225
Poids kg 240 285 345 500 600 950 1300 1550 2200 2850
Puissance 380V 50HZ 9,5 kW 11kW 17kW 20kW 26kW 36kW 59kW 98kW 135kW 177kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
OptionalPower 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase
En option SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW

 

Modèle SUNDI-955W SUNDI-975W SUNDI-9A10W SUNDI-9A15W SUNDI-9A25W SUNDI-9A38W SUNDI-9A60W SUNDI-9A80W
Temp range   -90℃~+250℃
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control Modèle de contrôle de la température du processus et de la température de l'enveloppe
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 5.5 7.5 10 15 25 38 60 80
Capacité de refroidissement 250℃ 5.5 7.5 10 15 25 38 60 80
0℃ 5.5 7.5 10 15 25 38 60 80
-60℃ 2.8 3.2 4.2 6 10 16 24 32
-80℃ 0.8 1.2 1.6 2.1 3.5 6 11 15
-85℃ 0.5 0.7 0.85 1.3 1.9 3.5 6 8
Flow、pressure max
L/min bar
35 50 60 110 150 250 400 400
1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5
Pompe de circulation Pompe à entraînement magnétique
Compresseur Emerson copeland/Carlyle
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R508B
Taille de la connexion ZG3/4 ZG1 ZG1 ZG1 DN32 PN10 DN40 PN10 DN65 PN10 DN65 PN10
Eau de refroidissement
@20℃
3400L/H
1,5bar~4bar
ZG1
4500L/H
1,5bar~4bar
ZG1
5200L/H
1,5bar~4bar
ZG1 1/4
8m³/H
1,5bar~4bar
DN40
12m³/H
1,5bar~4bar
DN50
20m³/H
1,5bar~4bar
DN65
30m³/H
1,5bar~4bar
DN80
40m³/H
1,5bar~4bar
DN100
Dimension en cm 80*120*185 80*120*185 80*120*185 150*100*185 200*145*205 200*145*205 250*160*225 300*160*225
Poids kg 365 570 680 950 1400 1750 2400 3150
Puissance 380V 50HZ 16kW 27kW 30kW 42kW 59kW 83kW 130kW 188kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
OptionalPower 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase
En option SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW

 

Modèle SUNDI-1055W SUNDI-1075W SUNDI-10A10W SUNDI-10A15W SUNDI-10A25W SUNDI-10A38W SUNDI-10A60W SUNDI-10A80W
Temp range   -100℃~+100℃
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Temp control Modèle de contrôle de la température du processus et de la température de l'enveloppe
Temp difference Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 20 programs, each program can edit 40 steps
Communication Protoco Protocole MODBUS RTU, interface RS485
Material temp feedback PT100
Temp feedback The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor)
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃
Puissance de chauffage 5.5 7.5 10 15 25 38 60 80
Capacité de refroidissement 100℃ 5.5 7.5 10 15 25 38 60 80
0℃ 5.5 7.5 10 15 25 38 60 80
-80℃ 2.8 3.4 4.1 5 8 13 22 30
-90℃ 1.2 1.6 2 3 4.8 7.5 12 16
 -95℃ 0.7 0.9 1.2 1.8 2.9 4.5 7.2 9.5
Flow、pressure max
L/min bar
35 50 60 110 150 250 400 400
1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5
Pompe de circulation Pompe à entraînement magnétique
Compresseur Emerson copeland/Carlyle
Soupape d'expansion Soupape d'expansion électronique
Évaporateur Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device,
high temperature protection and temperature fault protection.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R-404A/R23/R14
Taille de la connexion ZG3/4 ZG1 ZG1 DN32 DN32 DN40 DN65 DN65
Eau de refroidissement
@20℃
5000L/H
1.5~4bar
ZG1 1/4
7000L/H
1.5~4bar
DN40
9000L/H
1.5~4bar
DN40
12m³/H
1.5~4bar
DN50
20m³/H
1.5~4bar
DN65
25m³/H
1.5~4bar
DN65
40m³/H
1.5~4bar
DN80
50m³/H
1.5~4bar
DN100
Dimension en cm 80*120*185 150*100*185 150*100*185 200*145*205 200*145*205 250*160*225 300*160*225 400*160*225
Poids kg 565 705 890 1250 1600 2100 2950 3350
Puissance 380V 50HZ 26W 28kW 37kW 49kW 69kW 82kW 170 kW 200kW
Case materia Cold rolled steel powder coating (standard color 7035)
En option Optional Ethernet interface and computer operation software configuration
En option Outside touch screen display controller,
the communication line distance is 10 meter
Puissance optionnelle 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase
En option SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW

La technologie de refroidissement à ultra haute température peut refroidir directement à partir d'une température élevée de 300℃[car seul le fluide caloporteur dans la chambre d'expansion entre en contact avec l'oxygène de l'air (et la température du réservoir d'expansion est entre la température normale et 60℃), ce qui peut réduire le risque d'oxydation du fluide caloporteur et d'absorption de l'eau dans l'air. À haute température, aucun fluide caloporteur ne s'évapore, et la régulation continue de la température de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ et - 30℃ ~ 300℃ peut être réalisée sans pressurisation.

1. Affiche tous les types de températures de contrôle du processus.
2. Indique le niveau de liquide du fluide caloporteur dans le vase d'expansion.
3. Indique le fonctionnement du système de réfrigération.
4. Indique le fonctionnement de l'appareil de chauffage.
5. Indique le fonctionnement de la pompe de circulation.
6. Affiche le contrôle de la température (modèle de contrôle de la température des matériaux, contrôle de la température moyenne de la conduite de la chaleur).
7. La limite supérieure et la limite inférieure de la température peuvent être réglées.
8. La différence de température entre l'enveloppe et le matériau du réacteur peut être réglée.
9. Indique l'alarme pour ajouter le liquide lorsqu'il est vide.
10. Le compresseur frigorifique peut être réglé pour fonctionner manuellement ou automatiquement.

Nouveaux matériaux | Contrôle de la température de production des gaz spéciaux

Solution de contrôle de la température pour la production intermédiaire de l'API

Solution de contrôle de la température de la concentration de distillation

En savoir plus

En savoir plus


Depuis notre création en 2006Nous avons servi plus de 30 000 clients et détiennent plusieurs brevets qui témoignent de notre innovation et de notre fiabilité. Nos refroidisseurs sont sélectionnés pour plus de 100 université de laboratoires dans le monde entier et exportés dans plus de 20 pays. Nous garantissons la plus haute qualité grâce à une 3 étapes un processus de contrôle de la qualité : inspection visuelle, tests de performance et tests de sécurité électrique. Notre engagement en faveur de l'excellence est renforcé par nos Client 24/7 engagement de soutien. En outre, nous avons des agents aux États-Unis, au Canada, en Australie, en Russie et en Corée du Sud, ce qui fait de nous un partenaire mondial de confiance pour vos besoins en refroidisseurs. Choisissez Lneya pour la qualité et le soutien de votre projet.
18+

Années d'expérience

30000+

Des clients satisfaits

25000

m² Zone de production

80+

Technologies brevetées

*
*
Soumission....
Envoyé avec succès !
Échec de la soumission ! Veuillez réessayer plus tard
Erreur d'email !
Erreur de téléphone !