SUNDI series Chiller and Heater Combo Units
CANDIDATURES
Dynamic constant temperature control of cold and hot sources of high-pressure reactors;
Dynamic constant temperature control of cold and hot sources of double-layer glass reactors;
Dynamic constant temperature control of cold and hot sources of double-layer reactors;
Constant temperature control of cold and hot sources of microchannel reactors;
Small constant temperature control systems, distillation system temperature control;
Low-temperature and high-temperature aging tests of materials;
Constant temperature control of combined chemical cold and hot sources;
Cooling and heating of semiconductor equipment;
Constant temperature control of refrigeration and heating of vacuum chambers.
Caractéristiques du produit
Paramètres du produit
Modèle | SUNDI-320 SUNDI-320W | |
Temp range | -30℃~180℃ | |
Medium temp accuracy | ±0.5℃ | |
Material temp accuracy |
±1℃ |
|
Puissance de chauffage | 2kW | |
Refroidissement capacité |
180℃ | 1,5 kW |
50℃ | 1,5 kW | |
0℃ | 1,5 kW | |
-5℃ | 0.7kW | |
-15℃ | 0,4 kW | |
Flow、pressure | max10L/min 0,8bar |
|
Réfrigérant | R-404A/R507C | |
Taille de la connexion | ZG1/2 | |
Dimension en cm | 35*56*75 | |
Poids kg | 55 kg | |
Puissance | AC 220V 50HZ 3.2kW(max) |
Modèle | SUNDI-135 SUNDI-135W |
SUNDI-155 SUNDI-155W |
SUNDI-175 SUNDI-175W |
SUNDI-1A10 SUNDI-1A10W |
SUNDI-1A15 SUNDI-1A15W |
|
Temp range | -10℃~+150℃ | |||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | |||||
Temp control | Modèle de contrôle de la température du processus et de la température de l'enveloppe | |||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | |||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | |||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | |||||
Material temp feedback | PT100 | |||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||
Medium temp accuracy | ±0.5℃ | |||||
Material temp accuracy | ±1℃ | |||||
Puissance de chauffage | 3.5 | 5.5 | 7.5 | 10 | 15 | |
Refroidissement capacité |
150℃ | 3.5 | 5.5 | 7.5 | 10 | 15 |
20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | |
-5℃ | 2.1 | 3.3 | 4.2 | 6 | 9 | |
Flow、pressure max L/min bar |
35 | 35 | 50 | 50 | 75 | |
1 | 1 | 1.2 | 1.2 | 1.2 | ||
Compresseur | Highly / Panasonic / Emerson copeland / scroll compressor | |||||
Soupape d'expansion | Soupape d'expansion électronique | |||||
Évaporateur | Échangeur de chaleur à plaques | |||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | |||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | |||||
Réfrigérant | R-404A/R507C | |||||
Taille de la connexion | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | |
Eau de refroidissement @20℃ |
1300L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
1800L/H 1,5bar~4bar ZG3/4 |
2400L/H 1,5bar~4bar ZG3/4 |
3600L/H 1,5bar~4bar ZG1 |
|
Dimension en cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 70*85*185 | |
Poids kg | 165 | 185 | 235 | 280 | 300 | |
Puissance 380V 50HZ | 6.7kW | 9,5 kW | 12kW | 15.5kW | 23kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||
En option | Optional Ethernet interface and computer operation software configuration | |||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
|||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase |
Modèle | SUNDI-235 SUNDI-235W |
SUNDI-255 SUNDI-255W |
SUNDI-275 SUNDI-275W |
SUNDI-2A10 SUNDI-2A10W |
SUNDI-2A15 SUNDI-2A15W |
SUNDI-2A25 SUNDI-2A25W |
SUNDI-2A38W | SUNDI-2A60W | SUNDI-2A95W | SUNDI-2A130W | SUNDI-2A200W | |
Temp range | -25℃~+200℃(can be -25℃~+300℃) | |||||||||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | |||||||||||
Temp control | Modèle de contrôle de la température du processus et de la température de l'enveloppe | |||||||||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | |||||||||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | |||||||||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | |||||||||||
Material temp feedback | PT100 | |||||||||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||||||||
Medium temp accuracy | ±0.5℃ | |||||||||||
Material temp accuracy | ±1℃ | |||||||||||
Puissance de chauffage | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
Refroidissement capacité |
200℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
100℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
50℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
-5℃ | 3 | 4.5 | 6.3 | 8 | 11 | 19 | 30 | 46 | 70 | 80 | 125 | |
-15℃ | 1.8 | 2.8 | 3.8 | 4.6 | 7 | 12 | 16 | 22 | 32 | 43 | 65 | |
Flow、pressure max L/min bar |
35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Compresseur | Tecumseh Emerson copeland / Carlyle | |||||||||||
Soupape d'expansion | Soupape d'expansion électronique | |||||||||||
Évaporateur | Échangeur de chaleur à plaques | |||||||||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | |||||||||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||||||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | |||||||||||
Réfrigérant | R-404A/R507C | |||||||||||
Taille de la connexion | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | DN65 | DN65 | DN80 | |
Eau de refroidissement @20℃ |
1500L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
3000L/H 1,5bar~4bar ZG3/4 |
4200L/H 1,5bar~4bar ZG3/4 |
5400L/H 1,5bar~4bar DN32 |
10m³/H 1,5bar~4bar DN40 |
10m³/H 1,5bar~4bar DN40 |
14m³/H 1,5bar~4bar DN50 |
19m³/H 1,5bar~4bar DN65 |
24m³/H 1,5bar~4bar DN65 |
36m³/H 1,5bar~4bar DN80 |
|
Dimension en cm | 45*70*160 | 45*70*160 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
Poids kg | 165 | 185 | 230 | 280 | 300 | 550 | 750 | 1000 | 1250 | 1580 | 2150 | |
Puissance 380V 50HZ | 6.7kW | 9,5 kW | 15kW | 16kW | 27kW | 48kW | 55kW | 81kW | 126kW | 175kW | 260kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||||||||
En option | Optional Ethernet interface and computer operation software configuration | |||||||||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
|||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | |||||||||||
En option | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modèle | SUNDI-525 SUNDI-525W |
SUNDI-535 SUNDI-535W |
SUNDI-555 SUNDI-555W |
SUNDI-575 SUNDI-575W |
SUNDI-5A10 SUNDI-5A10W |
SUNDI-5A15 SUNDI-5A15W |
SUNDI-4A25 SUNDI-4A25W |
SUNDI-4A38W | SUNDI-4A60W | SUNDI-4A95W | SUNDI-4A130W | SUNDI-4A200W | |
Temp range | -45℃~+250℃ | ||||||||||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | ||||||||||||
Temp control | Modèle de contrôle de la température du processus et de la température de l'enveloppe | ||||||||||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | ||||||||||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | ||||||||||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | ||||||||||||
Material temp feedback | PT100 | ||||||||||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||||||
Medium temp accuracy | ±0.5℃ | ||||||||||||
Material temp accuracy | ±1℃ | ||||||||||||
Puissance de chauffage | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
Capacité de refroidissement | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
0℃ | 1.8 | 3 | 5 | 7 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
-20℃ | 0.85 | 1.5 | 2.3 | 3.6 | 5 | 7.6 | 11 | 20 | 29 | 42 | 54 | 98 | |
-35℃ | 0.25 | 0.45 | 0.9 | 1.5 | 2 | 3.8 | 4.7 | 9 | 12 | 18 | 24 | 43 | |
Flow、pressure max L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Pompe de circulation | Pompe à entraînement magnétique | ||||||||||||
Compresseur | Tecumseh/Emerson copeland/Carlyle | ||||||||||||
Soupape d'expansion | Soupape d'expansion électronique | ||||||||||||
Évaporateur | Échangeur de chaleur à plaques | ||||||||||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | ||||||||||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | ||||||||||||
Réfrigérant | R-404A/R507C | ||||||||||||
Taille de la connexion | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | DN32 | DN50 | DN50 | DN65 | DN65 | DN65 | |
Eau de refroidissement @20℃ |
900L/H 1,5bar~4bar ZG1/2 |
1400L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
2400L/H 1,5bar~4bar ZG3/4 |
3600L/H 1,5bar~4bar ZG1 |
4800L/H 1,5bar~4bar ZG1 |
9m³/H 1,5bar~4bar DN40 |
10m³/H 1,5bar~4bar DN50 |
15m³/H 1,5bar~4bar DN50 |
20m³/H 1,5bar~4bar DN65 |
32m³/H 1,5bar~4bar DN80 |
46m³/H 1,5bar~4bar DN100 |
|
Dimension en cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
Poids kg | 160 | 180 | 195 | 260 | 320 | 390 | 620 | 820 | 1100 | 1350 | 1680 | 2250 | |
Power 380V 50hz | AC220V 4kW | 7kW | 9kW | 13kW | 16kW | 26kW | 42kW | 57kW | 82kW | 136kW | 183kW | 309kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||||||
En option | Optional Ethernet interface and computer operation software configuration | ||||||||||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||||||
En option | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modèle | SUNDI-625 SUNDI-625W |
SUNDI-635 SUNDI-635W |
SUNDI-655 SUNDI-655W |
SUNDI-675 SUNDI-675W |
SUNDI-6A10 SUNDI-6A10W |
SUNDI-6A15W | SUNDI-6A25W | SUNDI-6A38W | SUNDI-6A60W | |
Temp range | -60℃~+250℃ | |||||||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | |||||||||
Temp control | Modèle de contrôle de la température du processus et de la température de l'enveloppe | |||||||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | |||||||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | |||||||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | |||||||||
Material temp feedback | PT100 | |||||||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||||||
Medium temp accuracy | ±0.5℃ | |||||||||
Material temp accuracy | ±1℃ | |||||||||
Puissance de chauffage | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
Capacité de refroidissement | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 |
100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
-40℃ | 0.95 | 1.45 | 2.3 | 3.1 | 4.8 | 7.8 | 18 | 23 | 31 | |
-55℃ | 0.25 | 0.5 | 0.75 | 0.9 | 1.5 | 2.8 | 6 | 8 | 11 | |
Flow、pressuremax L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | ||
Pompe de circulation | Pompe à entraînement magnétique | |||||||||
Compresseur | Tecumseh/Emerson copeland/Carlyle | |||||||||
Soupape d'expansion | Soupape d'expansion électronique | |||||||||
Évaporateur | Échangeur de chaleur à plaques | |||||||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | |||||||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | |||||||||
Réfrigérant | R-404A/R23 | |||||||||
Taille de la connexion | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | |
Eau de refroidissement @20℃ |
1100L/H 1,5bar~4bar ZG1/2 |
2000L/H 1,5bar~4bar ZG3/4 |
2300L/H 1,5bar~4bar ZG3/4 |
2600L/H 1,5bar~4bar ZG3/4 |
3300L/H 1,5bar~4bar ZG1 |
4000L/H 1,5bar~4bar ZG1 1/4 |
8,5m³/H 1,5bar~4bar DN40 |
14m³/H 1,5bar~4bar DN50 |
20m³/H 1,5bar~4bar DN65 |
|
Dimension en cm | 55*70*175 | 55*70*175 | 55*70*175 | 65*85*185 | 65*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Poids kg | 205 | 225 | 300 | 340 | 380 | 380 | 980 | 1350 | 1580 | |
Puissance 380V 50HZ | 5kW | 10kW | 12kW | 18kW | 22kW | 28kW | 56kW | 73kW | 110kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||||||
En option | Optional Ethernet interface and computer operation software configuration | |||||||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
|||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | |||||||||
En option | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modèle | SUNDI-825W | SUNDI-835W | SUNDI-855W | SUNDI-875W | SUNDI-8A10W | SUNDI-8A15W | SUNDI-8A25W | SUNDI-8A38W | SUNDI-8A60W | SUNDI-8A80W | |
Temp range | -80℃~+250℃ | ||||||||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | ||||||||||
Temp control | The material temperature control and equipment outlet temperature control modes can be freely selected | ||||||||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | ||||||||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | ||||||||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | ||||||||||
Material temp feedback | PT100 | ||||||||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||||
Medium temp accuracy | ±0.5℃ | ||||||||||
Material temp accuracy | ±1℃ | ||||||||||
Puissance de chauffage | 3 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacité de refroidissement | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-60℃ | 1 | 1.4 | 1.6 | 3 | 3.5 | 5.8 | 10 | 16 | 23 | 32 | |
-75℃ | 0.3 | 0.42 | 0.7 | 1.3 | 1.5 | 2.4 | 5 | 8 | 11 | 16 | |
Flow、pressuremax L/min bar |
20 | 35 | 35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Pompe de circulation | Pompe à entraînement magnétique | ||||||||||
Compresseur | Emerson copeland/Carlyle | ||||||||||
Soupape d'expansion | Soupape d'expansion électronique | ||||||||||
Évaporateur | Échangeur de chaleur à plaques | ||||||||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | ||||||||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | ||||||||||
Réfrigérant | R-404A/R508B | ||||||||||
Taille de la connexion | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN65 | DN65 | |
Eau de refroidissement @20℃ |
1800L/H 1,5bar~4bar ZG3/4 |
2000L/H 1,5bar~4bar ZG3/4 |
2800L/H 1,5bar~4bar ZG3/4 |
3500L/H 1,5bar~4bar ZG1 |
4200L/H 1,5bar~4bar ZG1 |
5600L/H 1,5bar~4bar DN32 |
10m³/H 1,5bar~4bar DN40 |
18m³/H 1,5bar~4bar DN65 |
28m³/H 1,5bar~4bar DN80 |
30m³/H 1,5bar~4bar DN80 |
|
Dimension en cm | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 245*170*225 | 300*160*225 | |
Poids kg | 240 | 285 | 345 | 500 | 600 | 950 | 1300 | 1550 | 2200 | 2850 | |
Puissance 380V 50HZ | 9,5 kW | 11kW | 17kW | 20kW | 26kW | 36kW | 59kW | 98kW | 135kW | 177kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||||
En option | Optional Ethernet interface and computer operation software configuration | ||||||||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||||
En option | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modèle | SUNDI-955W | SUNDI-975W | SUNDI-9A10W | SUNDI-9A15W | SUNDI-9A25W | SUNDI-9A38W | SUNDI-9A60W | SUNDI-9A80W | |
Temp range | -90℃~+250℃ | ||||||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | ||||||||
Temp control | Modèle de contrôle de la température du processus et de la température de l'enveloppe | ||||||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | ||||||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | ||||||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | ||||||||
Material temp feedback | PT100 | ||||||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||
Medium temp accuracy | ±0.5℃ | ||||||||
Material temp accuracy | ±1℃ | ||||||||
Puissance de chauffage | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacité de refroidissement | 250℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-60℃ | 2.8 | 3.2 | 4.2 | 6 | 10 | 16 | 24 | 32 | |
-80℃ | 0.8 | 1.2 | 1.6 | 2.1 | 3.5 | 6 | 11 | 15 | |
-85℃ | 0.5 | 0.7 | 0.85 | 1.3 | 1.9 | 3.5 | 6 | 8 | |
Flow、pressure max L/min bar |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Pompe de circulation | Pompe à entraînement magnétique | ||||||||
Compresseur | Emerson copeland/Carlyle | ||||||||
Soupape d'expansion | Soupape d'expansion électronique | ||||||||
Évaporateur | Échangeur de chaleur à plaques | ||||||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | ||||||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | ||||||||
Réfrigérant | R-404A/R508B | ||||||||
Taille de la connexion | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN65 PN10 | DN65 PN10 | |
Eau de refroidissement @20℃ |
3400L/H 1,5bar~4bar ZG1 |
4500L/H 1,5bar~4bar ZG1 |
5200L/H 1,5bar~4bar ZG1 1/4 |
8m³/H 1,5bar~4bar DN40 |
12m³/H 1,5bar~4bar DN50 |
20m³/H 1,5bar~4bar DN65 |
30m³/H 1,5bar~4bar DN80 |
40m³/H 1,5bar~4bar DN100 |
|
Dimension en cm | 80*120*185 | 80*120*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*160*225 | 300*160*225 | |
Poids kg | 365 | 570 | 680 | 950 | 1400 | 1750 | 2400 | 3150 | |
Puissance 380V 50HZ | 16kW | 27kW | 30kW | 42kW | 59kW | 83kW | 130kW | 188kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||
En option | Optional Ethernet interface and computer operation software configuration | ||||||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||
En option | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modèle | SUNDI-1055W | SUNDI-1075W | SUNDI-10A10W | SUNDI-10A15W | SUNDI-10A25W | SUNDI-10A38W | SUNDI-10A60W | SUNDI-10A80W | |
Temp range | -100℃~+100℃ | ||||||||
Mode de contrôle | Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC | ||||||||
Temp control | Modèle de contrôle de la température du processus et de la température de l'enveloppe | ||||||||
Temp difference | Régler ou contrôler la différence de température entre l'huile de gaine et la matière première. | ||||||||
Éditeur de programmes | 20 programs, each program can edit 40 steps | ||||||||
Communication Protoco | Protocole MODBUS RTU, interface RS485 | ||||||||
Material temp feedback | PT100 | ||||||||
Temp feedback | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||
Medium temp accuracy | ±0.5℃ | ||||||||
Material temp accuracy | ±1℃ | ||||||||
Puissance de chauffage | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacité de refroidissement | 100℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-80℃ | 2.8 | 3.4 | 4.1 | 5 | 8 | 13 | 22 | 30 | |
-90℃ | 1.2 | 1.6 | 2 | 3 | 4.8 | 7.5 | 12 | 16 | |
-95℃ | 0.7 | 0.9 | 1.2 | 1.8 | 2.9 | 4.5 | 7.2 | 9.5 | |
Flow、pressure max L/min bar |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Pompe de circulation | Pompe à entraînement magnétique | ||||||||
Compresseur | Emerson copeland/Carlyle | ||||||||
Soupape d'expansion | Soupape d'expansion électronique | ||||||||
Évaporateur | Échangeur de chaleur à plaques | ||||||||
Panneau de commande | Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données | ||||||||
Protection de la sécurité | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||
Système de circulation fermé | L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température. | ||||||||
Réfrigérant | R-404A/R23/R14 | ||||||||
Taille de la connexion | ZG3/4 | ZG1 | ZG1 | DN32 | DN32 | DN40 | DN65 | DN65 | |
Eau de refroidissement @20℃ |
5000L/H 1.5~4bar ZG1 1/4 |
7000L/H 1.5~4bar DN40 |
9000L/H 1.5~4bar DN40 |
12m³/H 1.5~4bar DN50 |
20m³/H 1.5~4bar DN65 |
25m³/H 1.5~4bar DN65 |
40m³/H 1.5~4bar DN80 |
50m³/H 1.5~4bar DN100 |
|
Dimension en cm | 80*120*185 | 150*100*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*160*225 | 300*160*225 | 400*160*225 | |
Poids kg | 565 | 705 | 890 | 1250 | 1600 | 2100 | 2950 | 3350 | |
Puissance 380V 50HZ | 26W | 28kW | 37kW | 49kW | 69kW | 82kW | 170 kW | 200kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||
En option | Optional Ethernet interface and computer operation software configuration | ||||||||
En option | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||
Puissance optionnelle | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||
En option | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
PRINCIPE DE FONCTIONNEMENT

La technologie de refroidissement à ultra haute température peut refroidir directement à partir d'une température élevée de 300℃[car seul le fluide caloporteur dans la chambre d'expansion entre en contact avec l'oxygène de l'air (et la température du réservoir d'expansion est entre la température normale et 60℃), ce qui peut réduire le risque d'oxydation du fluide caloporteur et d'absorption de l'eau dans l'air. À haute température, aucun fluide caloporteur ne s'évapore, et la régulation continue de la température de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ et - 30℃ ~ 300℃ peut être réalisée sans pressurisation.
Contrôle de l'écran couleur

1. Affiche tous les types de températures de contrôle du processus.
2. Indique le niveau de liquide du fluide caloporteur dans le vase d'expansion.
3. Indique le fonctionnement du système de réfrigération.
4. Indique le fonctionnement de l'appareil de chauffage.
5. Indique le fonctionnement de la pompe de circulation.
6. Affiche le contrôle de la température (modèle de contrôle de la température des matériaux, contrôle de la température moyenne de la conduite de la chaleur).
7. La limite supérieure et la limite inférieure de la température peuvent être réglées.
8. La différence de température entre l'enveloppe et le matériau du réacteur peut être réglée.
9. Indique l'alarme pour ajouter le liquide lorsqu'il est vide.
10. Le compresseur frigorifique peut être réglé pour fonctionner manuellement ou automatiquement.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Qu'il s'agisse de refroidisseurs portables, compacts, grands ou petits, nous pouvons les concevoir sur mesure en fonction de vos besoins. Quel que soit le nombre de tonnes de refroidisseurs dont vous avez besoin, nous pouvons créer la meilleure solution.
CUSTOM CHILLER TYPES
Nous fournissons des refroidisseurs de différents types de réfrigération, y compris, mais sans s'y limiter, des refroidisseurs à air, des refroidisseurs à eau et des refroidisseurs à condensation par évaporation. Quel que soit le type de compresseur frigorifique, nous pouvons le concevoir en fonction de vos besoins.
CUSTOM TEMPERATURE RANGES
Nous pouvons créer une solution personnalisée pour des températures allant de -150℃ à +350℃. Plages de températures personnalisées pour des industries spécifiques.
CUSTOM CHILLER VOLTAGE
Personnalisez la tension et la phase du refroidisseur en fonction de vos besoins. En option, 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
Pourquoi choisir Lneya comme fournisseur de systèmes de contrôle de la température ?
Années d'expérience
Des clients satisfaits
m² Zone de production
Technologies brevetées
Visite de l'usine LNEYA
nous contacter
Soumettez-nous votre demande et nous vous contacterons dans les 24 heures.
Recommander des produits