Recherche dans l'ensemble de la station

WTD series Cooling & Heating Temperature Control System for microchannel reactor

WTD series Cooling & Heating Temperature Control System for microchannel reactor

CANDIDATURES

Specially designed and developed for microchannel reactors with low liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system.Continuous high temperature cooling technology to meet the requirements of stable operation when hot and cold constant temperature control is required during high temperature exothermic reactions.

Modèle WTD-120M WTD-255 WTD-455 WTD-755 WTD-275V
Plage de température  -5°C~120°C -25°C~200°C -45°C~250°C -70°C~200°C  -20°C~300°C
Temp accuracy ±0.3℃
Temp resolution 0.1K
Control panel 7 inch colorful touch screen
Courbe de données Data Curve Record
Date output Disque U format excel
Control model PID Adaptive controller
Communication MODBUS RTU RS485
Capacité de chauffage 2kW 5,5 kW 5,5 kW 5,5 kW 7,5 kW
Capacité de refroidissement kW 300°C 7,5 kW
200°C 5,5 kW 5,5 kW 5,5 kW 7,5 kW
100°C 1,5 kW 5,5 kW 5 kW 5 kW 7,5 kW
20°C 1 kW 5,5 kW 5 kW 5 kW 5,5 kW
-15°C 2,5 kW 4 kW 4 kW 2,5 kW
-35°C 1,5 kW 3 kW
-60°C 1.1kW
Pompe de circulation max 7L/min 2.5bar 25L/min 3bar 25L/min 3bar 25L/min 3bar 25L/min 3bar
Taille de la connexion R1/2 R3/4 R3/4 R3/4 R3/4
Temp sensor PT100 PT100 PT100 PT100 PT100
Compresseur Emerson Copeland/Scope/Tecumseh
Évaporateur Échangeur de chaleur à plaques
Cooling way Refroidissement par air Air cooled+water cooled
Throttle type Soupape d'expansion thermique Electronic expansion valv
Filtre sec Danfoss
Heating-conduction medium Synthetic heat conducting oil
Réfrigérant R404A R404A R404A R404A R23 R404A
Matériau du tube SUS304 SUS304 SUS304 SUS304 SUS304
Metal insulated hose 1m*2 1.8M*2 1.8M*2 1.8M*2 1.8M*2
Contactor/circuit breaker Schneider Schneider Schneider Schneider Schneider
Dimension en cm 35*56*75 55*70*175 55*70*175 65*85*185 55*70*175
Poids kg 60KG 195KG 205KG 325KG 245KG
Puissance 380V 50HZ 220V 3.1kW 9.5kW  MAX 10kW  MAX 12kW  MAX 15kW  MAX
Matériau de l'étui Cold rolled steel powder coating (standard color 7035)

 

Modèle WTD-255-2T  Double Temp range
WTD-255W-2T  Double Temp range
WTD-455-2T  Double Temp range
WTD-455W-2T  Double Temp range
Plage de température -25°C~200°C  -45°C~250°C
Temp accuracy ±0.3℃
Temp resolution 0.1K
Control panel 7 inch colorful touch screen
Courbe de données Data Curve Record
Date output Disque U format excel
Control model PID Adaptive controller
Capacité de chauffage 5,5 kW 5,5 kW 5,5 kW 5,5 kW
Capacité de refroidissement kW 250°C 5,5 kW 5,5 kW
200°C 5,5 kW 5,5 kW 5,5 kW 5,5 kW
100°C 5kW 5kW 5 kW 5kW
20°C 5kW 5kW 5 kW 5kW
-15°C 2 kW 2 kW 4 kW 4kW
-35°C 1,5 kW 1,5 kW
Pompe de circulation max 25L/min 3bar    Double Line 25L/min 3bar   Double Line
Taille de la connexion R3/4  Double Line R3/4  Double Line
Temp sensor PT100 PT100
Displays temp. data of two lines of inlet and outlet liquid Displays temp. data of two lines of inlet and outlet liquid
Compresseur Emerson Copeland
Évaporateur Échangeur de chaleur à plaques Échangeur de chaleur à plaques
Cooling way Air cooled + Water cooled Air cooled + Water cooled
Throttle type Electronic expansion valv Electronic expansion valv
Filtre sec Danfoss
Heating-conduction medium Synthetic heat conducting oil
Réfrigérant R404A R404A
Matériau du tube SUS304 SUS304
Metal insulated hose 1.8M*4 1.8M*4
Contactor/circuit breaker Schneider Schneider
Dimension en cm 70*100*175 70*100*175
Poids kg 325KG 365KG
Puissance 380V 50HZ 19kW  MAX 20kW  MAX
Matériau de l'étui Cold rolled steel powder coating (standard color 7035)

 

Modèle WTD-2A38W-2TPEX WTD-4A38W-2TPEX WTD-7A50WPEX
Plage de température -25~200°C -25~200°C -45~200°C -45~200°C  -70~200°C
Temp accuracy ±0.5℃
Temp resolution 0.1K
Control panel Écran tactile couleur antidéflagrant Siemens 7 pouces
Courbe de données Data Curve Record
Date output Disque U format excel
Système de contrôle Lneya Control System Siemens PLC
System circulation fluid 30L+30L 30L+30L 50L
Volume du réservoir d'expansion 120L 120L 100L
Capacité de chauffage 38kW 38kW 38kW 38kW 50kW
Chauffage Electric Heater Heating power 3W/cm2
Actionneur de chauffage Voltage regulating actuator 4~20mA control
Capacité de refroidissement kW 200°C 38kW 38kW 38kW 38kW 50kW
100°C 38kW 38kW 38kW 38kW 50kW
20°C 38kW 38kW 38kW 38kW 50kW
-15°C 15kW 15kW 20kW 20kW 40kW
-35°C 11kW 11kW 25kW
-60°C 12kW
Pompe de circulation max 250L/min 3bar 250L/min 3bar 250L/min 3bar 250L/min 3bar 250L/min 3bar
Taille de la connexion DN50 PN16
Échangeur de chaleur pour l'eau de refroidissement Échangeur de chaleur à double tube
Volume d'eau de refroidissement 25m³/h  1BAR~4bar  max  DN65 PN10 28m³/h  1BAR~4bar  max   接口尺寸DN65 PN10 28m³/h1BAR~4bar  max DN65 PN10
Compresseur Emerson copeland scroll flexible compressor
Temp sensor PT100 Fluid temperature of each group of inlet and outlet
Throttle type Electronic expansion valv
Filtre sec Danfoss
Heating-conduction medium Huile synthétique de transfert de chaleur
Matériau du tube SUS304
Basse tension électrique Schneider/Siemens
Dimension en cm 250*200*220 250*200*220 250*200*220
Poids kg 2500KG 2600KG 2600KG
Puissance 380V 50HZ 110kW  MAX 125kW MAX 120kW MAX
Forme antidéflagrante Positive pressure explosion-proof, Explosion proof product installation license No. PCEC-2017-B025
Matériau de l'étui Cold rolled steel powder coating (standard color 7035)

La technologie de refroidissement à ultra haute température peut refroidir directement à partir d'une température élevée de 300℃[car seul le fluide caloporteur dans la chambre d'expansion entre en contact avec l'oxygène de l'air (et la température du réservoir d'expansion est entre la température normale et 60℃), ce qui peut réduire le risque d'oxydation du fluide caloporteur et d'absorption de l'eau dans l'air. À haute température, aucun fluide caloporteur ne s'évapore, et la régulation continue de la température de - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ et - 30℃ ~ 300℃ peut être réalisée sans pressurisation.

1. Affiche tous les types de températures de contrôle du processus.
2. Indique le niveau de liquide du fluide caloporteur dans le vase d'expansion.
3. Indique le fonctionnement du système de réfrigération.
4. Indique le fonctionnement de l'appareil de chauffage.
5. Indique le fonctionnement de la pompe de circulation.
6. Affiche le contrôle de la température (modèle de contrôle de la température des matériaux, contrôle de la température moyenne de la conduite de la chaleur).
7. La limite supérieure et la limite inférieure de la température peuvent être réglées.
8. La différence de température entre l'enveloppe et le matériau du réacteur peut être réglée.
9. Indique l'alarme pour ajouter le liquide lorsqu'il est vide.
10. Le compresseur frigorifique peut être réglé pour fonctionner manuellement ou automatiquement.

CANDIDATURES

Nouveaux matériaux | Contrôle de la température de production des gaz spéciaux

Solution de contrôle de la température pour la production intermédiaire de l'API

Solution de contrôle de la température de la concentration de distillation

En savoir plus

*
*
Soumission....
Envoyé avec succès !
Échec de la soumission ! Veuillez réessayer plus tard
Erreur d'email !
Erreur de téléphone !