The WTD vacuum chiller has a temperature control accuracy of up to ±0.3℃ and a temperature range of -70℃ to 300℃, giving you a more accurate, stable and efficient temperature control experience.
le plus bas
Le plus élevé
Précision du contrôle de la température
Medium & Material
Contact LNEYA sales engineer
for catalog or price.
Modèle | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Plage de température | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temp resolution | 0.1K | |||||
Control model | PID Adaptive controller | |||||
Capacité de chauffage | 2kW | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | |
Capacité de refroidissement kW | 300°C | 7,5 kW | ||||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | ||
100°C | 1,5 kW | 5,5 kW | 5 kW | 5 kW | 7,5 kW | |
20°C | 1 kW | 5,5 kW | 5 kW | 5 kW | 5,5 kW | |
-15°C | 2,5 kW | 4 kW | 4 kW | 2,5 kW | ||
-35°C | 1,5 kW | 3 kW | ||||
-60°C | 1.1kW | |||||
Pompe de circulation max | 7L/min 2.5bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | |
Temp sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Cooling way | Refroidissement par air | Air cooled+water cooled | ||||
Heating-conduction medium | Synthetic heat conducting oil | |||||
Puissance 380V 50HZ | 220V 3.1kW | 9.5kW MAX | 10kW MAX | 12kW MAX | 15kW MAX |
Floor space
The WTD recirculating chiller heater uses a plate heat exchanger with a compact structure and a small footprint, which is suitable for use in places with limited space. The bottom is equipped with 4 casters, which is convenient for you to move the position at any time according to your needs.
Core accessories
The accessories of the WTD industrial chiller heater are basically internationally renowned brands. For example, the compressor uses Secop, Emerson Copeland and French Tecumseh, etc.; the dry filter uses Danfoss; the contactor/circuit breaker uses Schneider.
Cannabis extraction
Cannabinoids and other active ingredients contained in cannabis are important for medical treatment, but a key factor in cannabis extraction is temperature control in processes such as extraction, distillation, crystallization, and solvent recovery. Only by accurately and stably controlling the temperature environment with the help of chiller heater units can we help improve the efficiency of extraction and the quality of products.
Médicaments
In the pharmaceutical process, researchers need to use laboratory thermostats to change the temperature environment, understand the stability of drugs at different temperatures, and observe the changes in their efficacy and activity.
30,000 +customers.
20+ countries.
CE ,SGS, ISO certification.
24/7 solutions.
15+ years experience.
Quality test.
Vous ne trouvez pas le refroidisseur qui vous convient ? Ou vous ne savez pas comment choisir ? Contactez-nous dès maintenant pour obtenir des informations et des tarifs.
Contacter LNEYA
Soumettez-nous votre demande et nous vous contacterons dans les 24 heures.