LNEYA isolation explosion-proof cooling heating circulation system SR-35N
LNEYA isolation explosion-proof cooling and heating circulation system mainly uses heat transfer medium for heating and refrigerant for cooling. So what are the main accessories in the isolated cold and hot water circulation system? What effect does it have?

1. Compressor accessories:
The compressor that isolates the explosion-proof cooling and heating circulation system is one of its main accessories, and its performance is more important. Adopting single-machine self-cascading refrigeration technology, the choice of compressor is very important.
2. Evaporator of accessories
Evaporation in the LNEYA isolation explosion-proof cooling and heating circulation system is the physical process of changing the liquid state to the gas state. Generally speaking, the evaporator is an object in which the liquid substance is in the gas state. There are many evaporators in the industry, one of which is the evaporator used in the cooling system, and the evaporator is one of the components of the refrigeration. The low-temperature condensate exchanges heat with the outside air through the evaporator, and the evaporation absorbs heat. The evaporator is mainly composed of a heating chamber and an evaporation chamber. The heating chamber provides the heat needed to evaporate the liquid to facilitate boiling and evaporation of the liquid.
3. Condenser accessories
The condenser is part of the cooling system of the isolated hot and cold water circulation system, which converts gas or steam into liquid and can transfer heat from the pipes to the nearby air.
4. Heat exchanger for accessories
The heat exchanger of LNEYA isolation explosion-proof cooling heating circulation system is mainly to transfer heat from hot fluid to cold fluid, the heat exchanger has a four-way valve, which can cool and heat exchanger.
Whether in biotechnology experiments or chemical pharmaceutical processes, as long as you need to control and adjust the temperature, you can contact us for the most suitable temperature control solution. Our email address is sales@lneya.com.
Recommandations connexes
-
Différentes fonctions de refroidissement et de chauffage du réacteur sur la température
1015Le refroidisseur de refroidissement et de chauffage du réacteur est une sorte de machine de réfrigération, car son composant principal utilise un compresseur à vis, qui peut être appelé refroidisseur à basse température du réacteur par son nom, et est largement utilisé dans les pro...
Voir les détails -
Précautions pour l'utilisation de systèmes chimiques de réfrigération et de chauffage par circulation
1067In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Voir les détails -
Wafer thin film deposition temperature control equipment chiller usage environment
1027Usage environment for wafer thin film deposition cooling chiller
Voir les détails -
Mode d'emploi du circulateur de chauffage et de refroidissement
1000Le circulateur de chauffage et de refroidissement est un processus par lequel le réfrigérant transfère la chaleur d'un état de basse température à un état de haute température, de sorte que son refroidissement puisse atteindre l'état de basse température de l'environnement, ce qui permet de maintenir l'état de basse température et de re...
Voir les détails