Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil level and oil difference of the chiller?

Oil level
It refers to the level of lubricating oil in the oil storage container. The oil storage containers of low-temperature chillers are equipped with oil level display devices. Generally, it is stipulated that the oil level in the oil storage container should be 5mm above and below the central horizontal line of the sight glass. The purpose of specifying the oil level is to ensure that when the oil pump is working, the amount of oil required to form an oil circulation is sufficient. If the oil level is too low, it is easy to cause insufficient oil pumps, which may cause operation failures or damage the equipment.
Oil pressure difference
It is the guarantee that lubricating oil needs to overcome the flow resistance when it flows to various working parts in the pipeline of the oil system under the drive of the oil pump. Without sufficient oil pressure difference, it is impossible to guarantee that the lubrication system of cold and low temperature chiller has sufficient lubrication and cooling oil and the power required to drive the energy regulating device. Therefore, the low temperature chiller manufacturer reminds that the oil pressure difference of the oil system It must be ensured in a reasonable range so that the moving parts of the unit can be fully lubricated and cooled, and the energy adjustment device can be manipulated flexibly.
Oil temperature
Oil temperature refers to the temperature of lubricating oil when the chiller is working. The oil temperature has an important influence on the viscosity of the lubricating oil. If the oil temperature is too low, the viscosity of the oil will increase, the fluidity will decrease, and it is not easy to form a uniform oil film, so the expected lubrication effect cannot be achieved, and it will also cause the oil flow speed to decrease, reduce the lubrication volume, and the power consumption of the oil pump. Increase; if the oil temperature is too high, the viscosity of the oil will decrease, and the oil film will not reach a certain thickness, making it difficult for the running parts to withstand the necessary working pressure, causing deterioration of the lubrication condition, aggravation of the moving parts, and failure of the chiller.
So let’s not say much, the chiller manufacturer believes that everyone also understands the impact of oil level and oil difference. In order to better use the chiller, you still need to understand these operating points carefully!
Recommandations connexes
-
Méthode de contrôle de l'arrêt du refroidisseur à eau d'une bouilloire à réaction unique
1314Le refroidisseur à eau de la bouilloire de réaction dispose d'une large gamme d'accessoires et d'équipements. En utilisation réelle, il doit bénéficier d'un temps de repos régulier. Afin de maintenir la stabilité des performances du réfrigérateur au cours d'un fonctionnement à long terme, il est...
Voir les détails -
Conseils de marque pour les congélateurs à ultra-basse température
885Lorsqu'il s'agit de congélateurs à très basse température, la plupart des gens s'inquiètent, car les températures très basses rendent la technologie plus difficile. Par rapport à d'autres installations frigorifiques, les choix de congélateurs à ultra basse température...
Voir les détails -
Traitement des gaz d'échappement insuffisants dans les compresseurs à chambre d'essai d'impact à haute et basse température
1218L'efficacité de la chambre d'essai d'impact à haute et basse température pendant l'utilisation est très importante. S'il y a un manque de gaz d'échappement du compresseur, nous avons besoin de nos techniciens LNEYA pour résoudre le problème à temps. Alors, comment mieux résoudre le problème ?
Voir les détails -
How to install -50 °C cryogenic unit manufacturers equipment?
1093-50 °C cryogenic units are used in the refrigeration and chemical industry, so what issues should be paid attention to during installation? LNEYA professional manufacturers tell you that you should install according to the instruction manual. For...
Voir les détails