What are the functions of the controllers for semiconductor temperature control equipment?
In the temperature control equipment of semiconductor components, each accessory has a different function. Due to the different functions, the function of the temperature control valve and controller of the semiconductor components of LNEYA is different.
The temperature-controlled water pump of the semiconductor component is a tool for accelerating the flow of water to enhance the heat transfer effect of the water in the heat exchanger. The water flow switch of the semiconductor temperature control device is used for the control or interruption protection of the fluid flow in the pipeline. When the fluid flow reaches the set value, the switch automatically cuts off (or turns on) the circuit. The pressure controller is used for pressure control and pressure protection. The unit has low pressure and high pressure controllers to control the working range of the system’s pressure. When the system pressure reaches the set value, the switch automatically cuts off (or turns on) the circuit.
The differential pressure controller of the semiconductor temperature control device is used as a pressure difference control, and when the pressure difference reaches the set value, the switch automatically cuts off (or turns on) the circuit. The temperature controller is used for control or protection of the unit. When the temperature reaches the set value, the switch automatically cuts off (or turns on) the circuit. In our products, temperature control is often used to control the unit’s start and stop conditions. Some still require a temperature controller like antifreeze.
The semiconductor temperature control device is used to indicate the condition of the refrigerant in the liquid line in the refrigeration device, the water content in the refrigerant, the flow condition of the lubricating oil from the oil separator in the return line, and some sight glass belts. There is an indicator that indicates the water content in the refrigerant by changing its color. (green means dry and yellow means wet). The volume change of water caused by temperature changes, the expansion tank is used to store this part of the expansion water, the system is regulated and fixed, and the system can compensate part of the water.
The semiconductor temperature control device is a relatively new device, and the performance above is required to be higher to be more stable.
Recommandations connexes
-
Large industrial freezer structural stability instructions
1255Large industrial refrigerators are used in the current industry. In order to maintain a smooth operation, the related structure also needs to maintain a stable state in order to stabilize and operate efficiently. The main structure of Wuxi Guanya ...
Voir les détails -
Refroidissement de la cuve de réaction en verre
852Chillers are used to cool glass reaction tanks. It is a common practice, especially in situations where precise temperature control is required during chemical reactions. Chillers can provide stable cooling effects to ensure that the tempera...
Voir les détails -
Description du prix de l'équipement Vocs et de l'effet de condensation
1153En tant que fabricant d'équipements vocaux, de nombreux utilisateurs accordent une attention particulière au prix des équipements vocaux lors de l'achat de ces derniers. Que savez-vous donc du prix et de l'effet de condensation des équipements vocaux et de l'importance de la performance ? Du...
Voir les détails -
100L high and low temperature thermostat installation instructions
861The 100L high and low temperature thermostat uses coolant as the transmission medium to transfer the heat generated by other instruments or equipment that need to be cooled, and dissipate the heat to the outside of the equipment through the refrig...
Voir les détails