TCU temperature control model selection and technical parameter description
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.

In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Recommandations connexes
-
Comment résoudre le phénomène de givrage du compresseur du congélateur 50p ?
1052Le congélateur 50p est utilisé dans le traitement industriel du froid, mais si ses performances ne sont pas bonnes, il peut entraîner des travaux industriels, surtout s'il est défectueux, il est plus difficile à résoudre. Par conséquent, il est préférable de comprendre les différents défauts du congélateur 50p...
Voir les détails -
Application du refroidisseur
1149Avec le développement rapide de la technologie industrielle moderne, afin d'améliorer l'efficacité de la production, la qualité des produits et de réduire les coûts de production, les exigences en matière de contrôle de la température dans le processus de production sont de plus en plus élevées.....
Voir les détails -
Principales différences entre les refroidisseurs d'intérieur et les refroidisseurs d'extérieur
897Bien que les refroidisseurs d'intérieur et les refroidisseurs d'extérieur soient tous deux des dispositifs utilisés pour fournir de l'eau froide afin de répondre à des besoins de refroidissement spécifiques, ils présentent des différences significatives en termes de conception, de lieu d'installation, d'environnement de travail et de méthodes de dissipation de la chaleur...
Voir les détails -
Wuxi Guanya (LNEYA): Ten years of wind and rain, all the way
862For Wuxi Guanya LNEYA, success has never been achieved overnight. For the development of Wuxi Guanya, after more than ten years of ups and downs, there are brilliant achievements in the field of refrigeration and heating temperature control. It is...
Voir les détails