Quels sont les principaux risques liés à la bouilloire de réaction dans le système de contrôle intelligent de la température du réacteur ?
The intelligent temperature control system of the reactor is used in various chemical fines. With the constant attention of the industry safety issues, some risk factors of the intelligent temperature control system of the reactor should be avoided in time.
In the pharmaceutical and chemical industry, it operates in various fine productions. In the chemical industry, there are many intelligent control systems for reactors, many storage tanks, and a wide network of pipe networks. From a structural point of view, the entire production system is composed of several production units. Reactor intelligent temperature control system Each production unit is composed of one or more reactors, a condenser and a rectification tower.
The material in the kettle is too fast, the cooling rate is low, and the condensation effect is poor, which may cause the material to boil, form a vapor-liquid mixture, generate pressure, weak links from the venting tube, vapor phase tube, safety valve, and blasting. The pressure relief system such as the sheet is subjected to pressure relief and compaction. If the material cannot reach the submerged fruit with rapid pressure relief, it may cause the explosion of the kettle body.
If the welding and gas cutting maintenance work is carried out without taking effective precautions during the material reaction process in the intelligent temperature control system of the reaction kettle, or the bolts and irons are hit and beat to generate sparks, once the inflammable and explosive materials are encountered May cause fire and explosion.

It should be noted that the feed temperature of the reactor intelligent temperature control system is too fast, the feed ratio is out of control, or the feed sequence is wrong. It is possible to generate a rapid exothermic reaction. If the cooling cannot be synchronized, heat accumulation will occur, causing the material to be partially decomposed by heat. The material reacts quickly and generates a large number of hazardous gas accidents.
In the operation of the intelligent temperature control system of the reaction kettle, when feeding, for the atmospheric pressure reaction, if the venting tube is not opened, when the liquid material is transported into the kettle by the pump at this time, the positive pressure is easily formed in the kettle, which may cause the connection of the material pipe. Cracking, material accidents cause burns caused by personal injury. When unloading, if the material in the kettle is unloaded when it is not cooled to the specified temperature, the material at higher temperature is easily deteriorated and it is easy to cause the material to splash and burn the operator.
We need to pay attention to the issue of production safety, and do a good job in safety in time to avoid personal injury caused by improper use.
Recommandations connexes
-
Description of refrigeration principle in semiconductor wafer temperature control
1287In the operation of the semiconductor wafer temperature control refrigeration system, a state transition of a certain working fluid is used, and the necessary heat Q0 is extracted from the heat source of a lower temperature, and the heat Qk is sen...
Voir les détails -
Refrigeration control system compressor failure caused by oil pressure
1018If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be clear...
Voir les détails -
Is it right to extend battery life by lowering the ambient temperature?
987The battery can work in a wide temperature range, but this does not allow the battery to be charged under high temperature conditions. The charging process is more delicate than the discharging process, and extreme care must be taken. Extreme cold...
Voir les détails -
LNEYA high and low temperature heating refrigerator maintenance instructions
1178High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high an...
Voir les détails