Instructions de chargement du réfrigérant pour les congélateurs à grande différence de température
Dans le cadre du développement de l'industrie moderne, les congélateurs à grande différence de température jouent également un rôle important dans le traitement du froid. Dans l'ensemble du processus de réfrigération du congélateur à grande différence de température, la charge du réfrigérant est également plus importante. Alors, comment...
For large-temperature-difference freezer refrigeration systems without high-pressure reservoirs and low-pressure vapor-liquid separators, the control of refrigerant charge is particularly important. Because the refrigeration system is a condenser and also acts as a high-pressure reservoir, the refrigerant is stored in the condenser, and the condenser is cooled. The heat dissipation area is reduced and the condensing pressure is increased, resulting in a decrease in cooling capacity.
For the control of the refrigerant charge of such a large temperature difference freezer, during the charging process, the temperature of the condenser casing should be touched, the upper outlet of the condenser outlet is heated, and the outlet below the outlet is cool (heating) It is indicated that there is a high-temperature exhaust gas of the compressor condensing inside, and the cooling is cold, indicating that the water-cooled large temperature difference refrigerator is a liquid space). Secondly, look at the suction pressure, which corresponds to the temperature of the refrigerant water in the evaporator (that is, corresponds to the evaporation temperature). Then, depending on the return temperature of the compressor of the large temperature difference refrigerator, the return pipe of the high temperature unit should be cooled and dew, but it can be dew condensation to the compressor return valve. The return pipe of the low temperature unit should be frosted, but the frost is compressed. The machine return valve is fine. If condensation or frost builds up on the compressor casing, liquid refrigerant will enter the crankcase, causing the compressor to run oil and liquid. For hermetic compressors, the motor terminals are also shorted. Although most of the closed unit terminals are sealed with a sealant, the possibility of a short circuit still exists due to the uncertainty of the sealing effect.
The above is the refrigerant charging method of Wuxi Guanya LNEYA finishing, hope to help everyone to run a large temperature difference freezer.

Recommandations connexes
-
Le refroidisseur d'eau à très basse température 60P consomme trop d'énergie et nécessite une attention particulière
91560p ultra-low temperature water chillers of different manufacturers have different performance configurations and different energy consumption. If you find that the energy consumption is too large, you must check in time to see if there is a probl...
Voir les détails -
Nous sommes LNEYA, un fabricant de refroidisseurs.
970There are many manufacturers of industrialchillers in the world, especially JULABO, huber, etc. that are known in theindustry. How much do you know about the production technology of industrialchillers? Now, in many industrial productions, indu...
Voir les détails -
Battery pack cooling water machine Chiller use precautions
976The battery pack cooling water machine Chiller is used for the new energy battery pack cooling system. The user needs to pay attention to avoid misuse during operation, which causes the battery pack cooling and circulating water machine Chiller to...
Voir les détails -
Talk about the main points of choice for circulating water chiller in laboratory
968Circulating water cooler is also called chiller. It is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. Currently there are many kinds of chillers in the market. How to buy a suitable ch...
Voir les détails