-80 °C refrigerator manufacturer operating equipment points
When the user chooses the -80 °C refrigerator, it is definitely necessary to have a reliable quality. Wuxi Guanya (LNEYA)-80 °C refrigerator should pay attention to its operation details during operation to avoid equipment failure caused by improper operation.
The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. – It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.
Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.
-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.

Recommandations connexes
-
How to use multiple reactors for high and low temperature integrated machine
1417Multiple reactors high and low temperature integrated machine temperature control system will be connected with thermal conductive synthetic oil and power supply before use, and multiple reactor high and low temperature integrated machine temperat...
Voir les détails -
Les travaux suivants doivent être effectués avant la mise en service des refroidisseurs industriels
10152. Pour le groupe compresseur avec circuit d'eau, vérifiez soigneusement si le circuit d'eau de refroidissement et le circuit d'eau réfrigérée contiennent de l'eau, si la pression de l'eau est normale, si le système de canalisation de l'eau de refroidissement et de l'eau réfrigérée est débloqué....
Voir les détails -
How to protect the zero-86 degree low temperature refrigerator?
1253The structure of the scroll compressor and the piston compressor in the low-to-86 degree low-temperature refrigerator is different, and it cannot be reversed. The reverse phase of the three-phase power supply of the low-zero-86 degree low-temperat...
Voir les détails -
Différentes fonctions de refroidissement et de chauffage du réacteur sur la température
1012Le refroidisseur de refroidissement et de chauffage du réacteur est une sorte de machine de réfrigération, car son composant principal utilise un compresseur à vis, qui peut être appelé refroidisseur à basse température du réacteur par son nom, et est largement utilisé dans les pro...
Voir les détails