13p semi-closed air-cooled compression condensing unit failure warning instructions
The 13p semi-closed air-cooled compression condensing unit is used in industrial cold processing. After using it for a long time, some problems will arise, Wuxi Guanya (LNEYA) reminds.
There is usually a high-pressure alarm on the 13p semi-closed air-cooled compression condensing unit, which is automatically activated in the event of an accident. When we start, we will find that there is a fault indicator that is turned off. Because there is a fault now, it lights up. Some smart technologies have a self-protection mechanism. For example, after the high-voltage warning fault light is on, It is no longer running, and it is also to protect the compression condensing unit.
As the operating personnel of the condensing unit, do not force it to open at this time. Instead, check the problem and start the machine after finding the problem. If you can’t find the problem, I suggest you contact the manufacturer’s customer service. According to different situations, the natural solution is different.
The 13p semi-closed air-cooled compression condensing unit is water-cooled and air-cooled. If it is an air-cooled compression condensing unit, the staff should check the ambient temperature used. It is necessary to dispose heat in time because the temperature is too high. it is good. There are also other situations where high pressure alarms occur, and the cooling water flow is too small (this should check if the water valve is open), and the condensing unit should be in an air circulation environment.
If there is a warning state for the water-cooled compression condensing unit, most of them may be due to the failure of the cooling water circulation. If the cooling water valve is not open, if there is no playing card, it will make the water shortage, there is no way to provide condensation. The crew is, of course, sometimes it is also a problem of cooling water. At this time, check if the cooling tower is faulty.
The relevant fault warnings of the compression condensing unit are as shown above. If the relevant faults are found, it is better to solve them in time.

Recommandations connexes
-
Why do special gases used in semiconductor manufacturing processes require chillers?
881When using special gases in semiconductor manufacturing processes, a chiller is required, mainly due to the following reasons: 3. Process requirements: In semiconductor manufacturing processes such as chemical vapor deposition...
Voir les détails -
Impact et solution de la surchauffe des gaz d'échappement des refroidisseurs industriels
1209Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chil...
Voir les détails -
Fonctionnement et entretien du système de refroidissement pour les essais à haute et basse température en alternance
1110La méthode de fonctionnement du système de refroidissement du refroidisseur pour les essais à haute et basse température en alternance : 1. Confirmer que l'état des vannes concernées dans l'unité répond aux exigences de démarrage. 2. Alimenter le dispositif de contrôle électrique de l'unité...
Voir les détails -
Instructions de contrôle de la température pour les réacteurs en acier inoxydable et les réacteurs en verre
1201Le réacteur est une sorte d'équipement de réaction dans la production industrielle. Il doit généralement être réfrigéré ou chauffé. Le fait que la température soit appropriée ou non affecte directement l'effet de la réaction. Par conséquent, si les conditions le permettent, il est généralement e...
Voir les détails