Le système de refroidissement du moteur teste l'effet de la température de condensation
The motor cooling system tests the condenser. Under normal conditions, the first half of the heat pipe is very hot, and its temperature has a slow and slow gradual decline in the balance of power. The heat sensitivity of the second half of the heat pipe is greatly reduced compared with the first half. It is because the refrigerant in the second half of the tube has gradually liquefied, and the condensation temperature and the supercooling temperature have been reached.
When the motor cooling system tests the condenser abnormally, one is that the first half is not too hot, and the second half is close to normal temperature (ambient temperature) because the compressor draws in wet steam refrigerant or the refrigerant amount is insufficient.
When the other is abnormal, the entire motor cooling system tests that the condenser is hot because of excessive refrigerant volume or low ventilation, or high ambient temperature.

In operation, the shell of the shell-and-tube condenser is warmer in the upper half and the lower half is warmer. In the abnormal condition, the entire housing is not too hot, because the refrigerant is not enough, and the other is not. Normally, the entire housing is very hot due to insufficient cooling water or poor heat dissipation (scale in the water pipe). Under normal conditions, the casing condenser is very hot, because the amount of cooling water is too small or the heat dissipation effect is poor.
Motor cooling system test Once the condenser is blocked, it will affect the motor cooling system test cooling effect, so whether it is temperature or blockage, we need regular inspection and maintenance.
Recommandations connexes
-
Installation method of heating and cooling temperature control system for automobile motor
1107In chemical and pharmaceutical, chemical laboratories, pilot plants and other industrial processes, the heating and cooling temperature control system is the most used equipment for temperature control in chemical manufacturing, so a highly dynami...
Voir les détails -
Rapid temperature change test chamber temperature control instructions
1118The selection of the humidity range of the rapid temperature change test chamber should be noted that the corresponding temperature range should be indicated after the humidity index or the dew point temperature should be given. Because relative h...
Voir les détails -
Selection method of 0℃~5℃ freezing liquid for industrial ultra-low temperature chiller
952As the requirements for process production become higher and higher, industrial ultra-low temperature chillers are required to provide cryogenic liquid below 5 degrees or even more than minus 100 degrees in some chemical process synthesis, reactor...
Voir les détails -
Utilisation des réfrigérateurs de traitement du froid pour les pièces mécaniques et comparaison avec l'azote liquide
975In the machinery manufacturing industry, the quality requirements for parts are very strict. In order to better improve the performance of machinery, improve product quality and life, a new technology-cryogenic treatment has been produced. During ...
Voir les détails