Fully closed cycle high viscosity fluid refrigeration heating flow control system
Application :
1. The tested object is connected to a test platform adapter.
2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and coolant.
Le composant testé doit passer par un profil de température spécifique et enregistrer les changements de température.
4. When conducting the tolerance test, perform the thermal shock test, and the rapid temperature drop control usually takes place in an infinite loop.
Visualisation, stockage des données et analyse des rapports
6, temperature control equipment can be flexibly connected to other test platforms
7. Equipped with a powerful circulation pump to ensure the delivery of high viscosity liquids.
8. The range of temperature changes is usually from -50 to 200 degrees (which can be made wider).
9. The proportional control valve is used to control the flow output, and the high-precision control total range is adjusted from 5% to 100%. The flow control range is large, and the minimum flow rate can be controlled from 3L/H to a maximum of 100m3/H.
10, pressure control 0.1bar ~ 20bar
11. The fully enclosed circulation system avoids the contact between the medium and the outside air, ensures no condensation, and avoids oxidation of the medium.

Recommandations connexes
-
Système de refroidissement du groupe motopropulseur de la transmission avec évaporateur
996L'évaporateur est l'un des quatre principaux composants du système de réfrigération et constitue l'incarnation ultime de l'effet et de l'efficacité de la réfrigération. L'évaporateur est généralement conçu et équipé par le groupe motopropulseur de la transmission ...
Voir les détails -
The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
1171In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chiller...
Voir les détails -
Destructive application effect of components in chip temperature measuring device
990The components can be tested in high-temperature and low-temperature cold sources in the microfluidic chip temperature measuring device. The destructive analysis of components is also an important application, which can measure the design, structu...
Voir les détails -
What to do When the High Pressure Alarm of the Chiller?
1321People must pay attention to the maintenance of large-scale temperature control equipment such as industrial water chiller. Sometimes it is normal to encounter high-pressure alarm. We must first find out the causes of high-pressure of the industri...
Voir les détails