Semiconductor refrigeration temperature control table cooler operation instructions
The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching between the active and standby working power sources. When the common power failure occurs, it automatically switches to the standby power supply. When both power supplies are normal, the common power supply works and the standby power supply is in standby state. The semiconductor refrigeration temperature control station programmable controller (PLC) is the control center of the execution part of the strong oil air cooler control device. It receives various status signals from the transformer to control the execution part.
When the transformer of the semiconductor refrigeration temperature control console is put into operation, a group of coolers will be put into operation, that is, the working group cooler is operated. The auxiliary cooler is controlled according to the oil surface temperature of the transformer, the winding temperature, the load signal, etc., and the auxiliary cooler can be activated as follows. The cooling method of the semiconductor refrigeration temperature control transformer is forced oil circulation air cooling, and at least one group of coolers should be operated after the transformer is put into operation. The control box of the semiconductor refrigeration temperature control station is controlled by intelligent equipment, and the cooling device for controlling the transformer is mainly controlled by a main switch such as a change switch on the control panel.

The structure and operation description of the semiconductor refrigeration temperature control station are as shown above. When the user operates the semiconductor refrigeration temperature control station, the operating efficiency of each component is ensured as much as possible, so that the overall operating efficiency of the semiconductor refrigeration temperature control station can be improved.
Recommandations connexes
-
Selection Guide for Laboratory Cooling and Heating Circulator
1073When purchasing laboratory cooling and heating circulator equipment, the key point is to meet production requirements and accelerate production output. Therefore, you need to understand the characteristics of the equipment and technical solutions ...
Voir les détails -
Leakage Detection Tips of Low Temperature Freezer
1188Pressure leaking detectionIt is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The le...
Voir les détails -
Contrôle de la température des éléments de test de la qualité et de la fiabilité des plaquettes de circuits intégrés/puces
1263La partie la plus élémentaire de la fabrication d'une puce est la conception, le ruban, l'emballage et le test. La structure des coûts d'une puce est généralement la suivante : 20% de coût de main-d'œuvre, 40% de bande, 35% d'emballage et 5% de test. Le test est en fait l'étape la plus importante dans tous les aspects de la puce. L'étape "bon marché", mais le...
Voir les détails -
La raison de l'alarme de haute pression de l'unité de contrôle de la température intégrée TCU
1011Lorsque l'unité de contrôle de la température intégrée TCU est utilisée, elle doit l'être conformément aux instructions détaillées. Lorsque des problèmes sont rencontrés, ils doivent être traités à temps. En règle générale, si nous rencontrons une alarme de haute pression de...
Voir les détails